A comparison of the INVOS 4100 and the NIRO 300 near-infrared spectrophotometers.

Kenji Yoshitani1, Masahiko Kawaguchi, Kazuyuki Tatsumi, Katsuyasu Kitaguchi, Hitoshi Furuya.   

Abstract

UNLABELLED: We determined whether two different devices for measuring near-infrared spectroscopy (NIRS)---the INVOS 4100 and the NIRO 300---produce similar cerebral oxygenation data during the CO(2) challenge test. Nineteen patients anesthetized with sevoflurane, 67% nitrous oxide in oxygen, and fentanyl were studied. A series of measurements of regional cerebral oxygen saturation (rSO(2)), measured by the INVOS 4100, and tissue oxygen index (TOI), measured by the NIRO 300, were performed in the following conditions: 1) normocapnia (PaCO(2), 35--45 mm Hg); 2) hypocapnia (PaCO(2), 25--35 mm Hg); 3) normocapnia; and 4) hypercapnia (PaCO(2), 45--55 mm Hg). Hemodynamic variables, including arterial blood gases and cerebral blood flow velocity, were measured at the same time with transcranial Doppler. The values and percentage changes of rSO(2) and TOI were compared by using regression analysis and Bland and Altman analysis. The rSO(2) showed a significant positive correlation with TOI (r = 0.58, P < 0.01). The percentage change of rSO(2) also showed a significant positive correlation with the percentage change of TOI during the CO(2) challenge (r = 0.85, P < 0.01). Bland and Altman analysis revealed a bias of -0.5% with 2 SD of 15.6% when comparing the rSO(2) value with the TOI value, and it showed a bias of -3.4% with 2 SD of 15.2% when comparing the percentage change of rSO(2) with the percentage change of TOI, indicating unacceptable disagreement of these data. These results indicate that cerebral oxygen saturation and its relative change during the CO(2) challenge may vary depending on the type of NIRS used. Because the measurement technique and algorithm were different in each device, we should carefully consider the clinical application of the values produced by NIRS. IMPLICATIONS: Near-infrared spectroscopy (NIRS) has been proposed as a noninvasive clinical method for assessing cerebral oxygenation. The acceptable reliability and validity of NIRS values have not been established despite their widespread use. The INVOS 4100 and the NIRO 300 can display cerebral oxygen saturation as regional cerebral oxygen saturation and tissue oxygenation index, but they produce differing results.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11867380     DOI: 10.1097/00000539-200203000-00020

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  34 in total

1.  Comparison of two spatially resolved NIRS oxygenation indices.

Authors:  Roy E Gagnon; Andrew J Macnab; Faith A Gagnon; Derek Blackstock; Jacques G LeBlanc
Journal:  J Clin Monit Comput       Date:  2002-12       Impact factor: 2.502

Review 2.  The clinical validity of the absolute value of near infrared spectroscopy.

Authors:  Kenji Yoshitani; Yoshihiko Ohnishi
Journal:  J Anesth       Date:  2008-11-15       Impact factor: 2.078

3.  Calibration of a prototype NIRS oximeter against two commercial devices on a blood-lipid phantom.

Authors:  Simon Hyttel-Sorensen; Stefan Kleiser; Martin Wolf; Gorm Greisen
Journal:  Biomed Opt Express       Date:  2013-08-14       Impact factor: 3.732

4.  Post-disaster depression and vigilance: a functional near-infrared spectroscopy study.

Authors:  William S Helton; Ulrike Ossowski; Sanna Malinen
Journal:  Exp Brain Res       Date:  2013-02-24       Impact factor: 1.972

5.  Validation of Near-Infrared Spectroscopy for Monitoring Cerebral Autoregulation in Comatose Patients.

Authors:  Lucia Rivera-Lara; Romergryko Geocadin; Andres Zorrilla-Vaca; Ryan Healy; Batya R Radzik; Caitlin Palmisano; Marek Mirski; Wendy C Ziai; Charles Hogue
Journal:  Neurocrit Care       Date:  2017-12       Impact factor: 3.210

Review 6.  Cerebral Oximetry and Autoregulation during Cardiopulmonary Bypass: A Review.

Authors:  Nousjka P A Vranken; Patrick W Weerwind; Nadia A Sutedja; Ervin E Ševerdija; Paul J C Barenbrug; Jos G Maessen
Journal:  J Extra Corpor Technol       Date:  2017-09

7.  Comparison of Cerebral Oximeter and Pulse Oximeter Values in the First 72 Hours in Premature, Asphyctic and Healthy Newborns.

Authors:  A Kaya; M Okur; E Sal; E Peker; M Köstü; O Tuncer; E Kırımi
Journal:  West Indian Med J       Date:  2014-09-03       Impact factor: 0.171

8.  Muscle perfusion and oxygen consumption by near-infrared spectroscopy in septic-shock and non-septic-shock patients.

Authors:  Massimo Girardis; Laura Rinaldi; Stefano Busani; Ivana Flore; Stefano Mauro; Alberto Pasetto
Journal:  Intensive Care Med       Date:  2003-05-28       Impact factor: 17.440

9.  Cerebral oxygenation and haemodynamic effects induced by nimodipine in healthy subjects.

Authors:  Daniela Canova; Silvestro Roatta; Giuseppe Micieli; Daniele Bosone
Journal:  Funct Neurol       Date:  2012 Jul-Sep

10.  Frontal cerebral oxygen response as an indicator of initial attention effort during perceptual learning.

Authors:  Michael Ong; Paul N Russell; William S Helton
Journal:  Exp Brain Res       Date:  2013-06-28       Impact factor: 1.972

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.