Literature DB >> 11866156

World experience with low contact stress mobile-bearing total knee arthroplasty: a literature review.

James B Stiehl1.   

Abstract

This article reviews recent data regarding the low contact stress (LCS) mobile-bearing total knee prosthesis recently published in the literature; conclusions are based on literature controls. The LCS Total Knee System (DePuy Orthopaedics Inc, Warsaw, Ind) has addressed the issues of implant polyethylene wear and implant-generated osteolysis. Patellar implant complications have been minimal despite the use of a mobile, metal-backed component. The original US Food and Drug Administration clinical investigation demonstrated favorable experience with cementless fixation. Results from numerous series indicate that the main problem with a mobile-bearing device is an early prosthetic failure resulting from bearing dislocation or breakage. Inadequate surgical technique will lead to femorotibial malalignment or ligamentous instability, which are factors that commonly result in revision. With the LCS Total Knee System, surgeons can use a tibia-cut-first approach with careful ligamentous balancing and flexion block spacing. The valgus lateral knee approach is an additional technique that has proved useful with this method.

Entities:  

Mesh:

Year:  2002        PMID: 11866156     DOI: 10.3928/0147-7447-20020202-04

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

1.  Sex-related outcome differences after implantation of low-contact-stress mobile-bearing total knee arthroplasty.

Authors:  Norbert Kastner; Gerald Gruber; Birgit A Aigner; Jörg Friesenbichler; Michael Pechmann; Florentine Fürst; Patrick Vavken; Andreas Leithner; Patrick Sadoghi
Journal:  Int Orthop       Date:  2012-01-25       Impact factor: 3.075

2.  Gender-specific outcome after implantation of low-contact-stress mobile-bearing total knee arthroplasty with a minimum follow-up of ten years.

Authors:  Norbert Kastner; Birgit A Aigner; Tobias Meikl; Jörg Friesenbichler; Matthias Wolf; Mathias Glehr; Gerald Gruber; Andreas Leithner; Patrick Sadoghi
Journal:  Int Orthop       Date:  2014-07-16       Impact factor: 3.075

Review 3.  [From tibiofemoral instability to dislocation in total knee arthroplasty].

Authors:  M Pietsch; S Hofmann
Journal:  Orthopade       Date:  2007-10       Impact factor: 1.087

4.  Radiolucent lines in low-contact-stress mobile-bearing total knee arthroplasty: a blinded and matched case control study.

Authors:  Patrick Sadoghi; Andreas Leithner; Patrick Weber; Jörg Friesenbichler; Gerald Gruber; Norbert Kastner; Katrin Pohlmann; Volkmar Jansson; Bernd Wegener
Journal:  BMC Musculoskelet Disord       Date:  2011-06-29       Impact factor: 2.362

  4 in total