Literature DB >> 11866070

Electrochemical oxidation of chlorophenols at a boron-doped diamond electrode and their determination by high-performance liquid chromatography with amperometric detection.

C Terashima1, Tata N Rao, B V Sarada, D A Tryk, A Fujishima.   

Abstract

Anodically pretreated diamond electrodes have been used for the detection of chlorophenols (CPs) in environmental water samples after high-performance liquid chromatographic (HPLC) separation. The anodization of as-deposited boron-doped polycrystalline diamond thin-film electrodes has enabled the stable determination of phenols over a wide concentration range. Prior to the HPLC analysis, a comparative study with ordinary glassy carbon, as-deposited diamond, and anodized diamond was made to examine the oxidative behavior of phenols by cyclic voltammety and flow injection analysis with amperometric detection. At anodized diamond electrodes, reproducible, well-defined cyclic voltammograms were obtained even at high CP concentration (5 mM), due to a low proclivity for adsorption of the oxidation products on the surface. In addition, after prolonged use, the partially deactivated diamond could be reactivated on line by applying a highly anodic potential (2.64 Vvs SCE) for 4 min, which enabled the destruction of the electrodeposited polymer deposits. Hydroxyl radicals produced by the high applied potential, in which oxygen evolution occurs, are believed to be responsible for the oxidation of the passivating layer on the surface. When coupled with flow injection analysis (FIA), anodized diamond exhibited excellent stability, with a response variability of 2.3% (n = 100), for the oxidation of a high concentration (5 mM) of chlorophenol. In contrast, glassy carbon exhibited a response variability of 39.1%. After 100 injections, the relative peak intensity, for diamond decreased by 10%, while a drastic decrease of 70% was observed for glassy carbon. The detection limit obtained in the FIA mode for 2,4-dichlorophenol was found to be 20 nM (S/N = 3), with a linear dynamic range up to 100 microM. By coupling with the column-switching technique, which enabled on-line preconcentration (50 times), the detection limit was lowered to 0.4 nM (S/N = 3). By use of this technique, anodized diamond electrodes were demonstrated for the analysis of CPs in drainwater that was condensed from the flue gas of waste incinerators.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11866070     DOI: 10.1021/ac010681w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Fluorometric determination of hydroquinone by using blue emitting N/S/P-codoped carbon dots.

Authors:  Yongping Wang; Qiaoli Yue; Lixia Tao; Cong Zhang; Chen-Zhong Li
Journal:  Mikrochim Acta       Date:  2018-11-15       Impact factor: 5.833

2.  Trimethyloxonium-mediated methylation strategies for the rapid and simultaneous analysis of chlorinated phenols in various soils by electron impact gas chromatography-mass spectrometry.

Authors:  Carlos A Valdez; Edmund P Salazar; Roald N Leif
Journal:  Sci Rep       Date:  2022-01-26       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.