Literature DB >> 11864353

Nosocomial legionellosis outbreak over a three-year period: investigation and control.

Philippe Berthelot1, Florence Grattard, Alain Ros, Frédéric Lucht, Bruno Pozzetto.   

Abstract

OBJECTIVE: To investigate the epidemiologic relatedness of nosocomial infections due to Legionella pneumophila serogroup 1 diagnosed between 1992 and 1994 in six immunocompromised patients of the same hospital and to describe the measures which were developed to control the outbreak.
METHODS: Legionella strains isolated from patients and from potable hot water were compared using three typing methods: monoclonal antibody analysis, arbitrarily primed PCR and ribotyping.
RESULTS: Environmental investigations revealed the presence of high levels of L. pneumophila serogroup 1 in hot water. The typing methods gave concordant results for demonstrating (1) the persistence of an epidemic strain of L. pneumophila serogroup 1 in the major water distribution circuit of the hospital over a 3-year period, and (2) the identity between patients' and environmental strains. Five of the six patients were probably infected via aerosols of hot tap water following inappropriate therapeutic procedures. Repetitive heat flushings associated with regular bacteriologic surveillance allowed correct disinfection of the water distribution systems. Specific recommendations concerning aerosol delivery and oxygen therapy were implemented in order to prevent further nosocomial legionellosis.
CONCLUSIONS: The same strain of L. pneumophila had been able to colonize the main water circuit of the hospital for at least 3 years; the relatedness between clinical and environmental strains was easily confirmed by the use of molecular markers.

Entities:  

Year:  1998        PMID: 11864353     DOI: 10.1111/j.1469-0691.1998.tb00082.x

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  3 in total

1.  High-resolution in situ genotyping of Legionella pneumophila populations in drinking water by multiple-locus variable-number tandem-repeat analysis using environmental DNA.

Authors:  Leila Kahlisch; Karsten Henne; Josefin Draheim; Ingrid Brettar; Manfred G Höfle
Journal:  Appl Environ Microbiol       Date:  2010-07-23       Impact factor: 4.792

2.  Longitudinal evaluation of the efficacy of heat treatment procedures against Legionella spp. in hospital water systems by using a flow cytometric assay.

Authors:  Severine Allegra; Florence Grattard; Françoise Girardot; Serge Riffard; Bruno Pozzetto; Philippe Berthelot
Journal:  Appl Environ Microbiol       Date:  2010-12-23       Impact factor: 4.792

Review 3.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

  3 in total