Literature DB >> 11863308

A new technique for the quantification of peripheral edema with application in both unilateral and bilateral cases.

Bruce H Cornish1, Brian J Thomas, Leigh C Ward, Cherrell Hirst, Ian H Bunce.   

Abstract

Current noninvasive techniques for the routine and frequent quantification of peripheral lymphedema in patients are total limb volume measurement (by water immersion or by circumferential measurements) and bioelectrical impedance analysis (BIA). However both of these techniques require standardizing the measurement using a contralateral measurement from the unaffected limb. Hence these techniques are essentially restricted to unilateral lymphedema. This paper describes the results from a preliminary study to investigate an alternative approach to the analysis of the data from multiple frequency BIA to produce an index of lymphedema without the need for normalization to another body segment. Twenty patients receiving surgical treatment for breast cancer were monitored prior to surgery and again after diagnosis with unilateral lymphedema. The data recorded were total limb volume, by circumferential measurements; and BIA measurements of both limbs. From these measurements total limb volumes and extracellular fluid volumes were calculated and expressed as ratios of the affected limb to that of the unaffected limb. An index of the ratio of the extracellular fluid volume to the intracellular fluid volume was determined. This ECW/ICW index was calculated for both the affected and unaffected limbs at both measurement times. Results confirmed that the established techniques of total limb volume and extracellular fluid volume normalized to the unaffected contralateral limb were accurate in the detection of lymphedema (p < 10(-6)). Comparison of the ECW/ICW index from the affected limb after diagnosis with that from the pre-surgery measurement revealed a significant (p < 10(-6)) and considerable (75%) increase. The results of this pilot study suggest that by using multiple frequency bioelectrical impedance analysis, an index of the ECW/ICW ratio can be obtained and this index appears to have an equal, or better, sensitivity than the other techniques in detecting lymphedema. More importantly, this index does not require normalization to another body segment and can be used to detect all types of peripheral edema including both unilateral and bilateral lymphedema.

Entities:  

Mesh:

Year:  2002        PMID: 11863308     DOI: 10.1177/000331970205300106

Source DB:  PubMed          Journal:  Angiology        ISSN: 0003-3197            Impact factor:   3.619


  10 in total

1.  Prediction of limb lean tissue mass from bioimpedance spectroscopy in persons with chronic spinal cord injury.

Authors:  Christopher M Cirnigliaro; Michael F La Fountaine; Racine Emmons; Steven C Kirshblum; Pierre Asselin; Ann M Spungen; William A Bauman
Journal:  J Spinal Cord Med       Date:  2013-09       Impact factor: 1.985

2.  Comparison of diagnostic accuracy of clinical measures of breast cancer-related lymphedema: area under the curve.

Authors:  Betty J Smoot; Josephine F Wong; Marylin J Dodd
Journal:  Arch Phys Med Rehabil       Date:  2011-04       Impact factor: 3.966

3.  Water Distribution Changes in Complex Decongestive Treatment for Leg Lymphedema: Quantitative Evaluation by Direct Segmental Multi-Frequency Bioimpedance Analysis.

Authors:  Masahiro Toshima; Yoshihisa Morino
Journal:  Ann Vasc Dis       Date:  2022-06-25

4.  Impedance of Extracellular Fluid, Volume, and Local Tissue Water Can Be Reliably Measured in People With Lower Limb Lymphedema.

Authors:  Charlotta Jönsson; Karin Johansson; Maria Bjurberg; Christina Brogårdh
Journal:  Phys Ther       Date:  2022-05-05

5.  Assessment of edema volume in skin upon injury in a mouse ear model with optical coherence tomography.

Authors:  Wan Qin; Ruikang K Wang
Journal:  Lasers Med Sci       Date:  2016-06-09       Impact factor: 3.161

6.  Normal values for segmental bioimpedance spectroscopy in pediatric patients.

Authors:  Maria Laura Avila; Leigh C Ward; Brian M Feldman; Madeline I Montoya; Jennifer Stinson; Alex Kiss; Leonardo R Brandão
Journal:  PLoS One       Date:  2015-04-13       Impact factor: 3.240

7.  A model of spontaneous mouse mammary tumor for human estrogen receptor- and progesterone receptor-negative breast cancer.

Authors:  Lixiang Zheng; Bugao Zhou; Xianming Meng; Weifeng Zhu; Airen Zuo; Xiaomin Wang; Runde Jiang; Shiping Yu
Journal:  Int J Oncol       Date:  2014-09-17       Impact factor: 5.650

8.  A randomized cross-over trial to detect differences in arm volume after low- and heavy-load resistance exercise among patients receiving adjuvant chemotherapy for breast cancer at risk for arm lymphedema: study protocol.

Authors:  Kira Bloomquist; Sandi Hayes; Lis Adamsen; Tom Møller; Karl Bach Christensen; Bent Ejlertsen; Peter Oturai
Journal:  BMC Cancer       Date:  2016-07-22       Impact factor: 4.430

9.  The Impact of L-Dex(®) Measurements in Assessing Breast Cancer-Related Lymphedema as Part of Routine Clinical Practice.

Authors:  Alison Laidley; Beth Anglin
Journal:  Front Oncol       Date:  2016-09-05       Impact factor: 6.244

10.  Use of a prospective surveillance model to prevent breast cancer treatment-related lymphedema: a single-center experience.

Authors:  Eun Joo Yang; Soyeon Ahn; Eun-Kyu Kim; Eunyoung Kang; Youngmi Park; Jae-Young Lim; Sung-Won Kim
Journal:  Breast Cancer Res Treat       Date:  2016-09-24       Impact factor: 4.872

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.