Literature DB >> 11862884

Wear evaluation of MZ100 compared to ceramic CAD/CAM materials.

K H Kunzelmann1, B Jelen, A Mehl, R Hickel.   

Abstract

The material and antagonist wear of two CAD/CAM ceramic materials, the laboratory-processed IPS Empress ceramic, and the composite mill block material MZ100 were tested in an artificial wear simulator with human enamel as the antagonistic material. The material samples underwent 50,000 test cycles (1 cycle per second, 50 N) in distilled water. The wear of the material samples and of the opposing enamel was documented after 30,000 and 50,000 cycles with replicas, digitized, and evaluated with a 3D evaluation system. The loss of volume and height caused by wear was calculated. No significant difference between the ceramic materials could be found either in the amount of material or in the amount of antagonist wear. The material wear of MZ100 differed significantly from Vita Mark II only in terms of volume loss. Regarding height loss, MZ100 exhibited a significantly higher wear than all ceramic materials. The wear of the enamel antagonists does not differ significantly between the ceramic materials. With MZ100, however, a significantly smaller amount of enamel wear was found when compared with Empress and Vita Mark II. Despite the highest material wear, MZ100 had the lowest material wear rate, the lowest enamel wear rate, and the lowest total wear rate. The laboratory-processed IPS Empress material had a clearly higher material wear rate than the CAD/CAM materials.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11862884

Source DB:  PubMed          Journal:  Int J Comput Dent        ISSN: 1463-4201            Impact factor:   1.883


  6 in total

1.  Polishing effects and wear performance of chairside CAD/CAM materials.

Authors:  Mike Matzinger; Sebastian Hahnel; Verena Preis; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2018-05-16       Impact factor: 3.573

Review 2.  Tooth Wear and Tribological Investigations in Dentistry.

Authors:  Ran Wang; Yuanjing Zhu; Chengxin Chen; Yu Han; Hongbo Zhou
Journal:  Appl Bionics Biomech       Date:  2022-06-09       Impact factor: 1.664

3.  Fatigue resistance of CAD/CAM resin composite molar crowns.

Authors:  Fatma A Shembish; Hui Tong; Marina Kaizer; Malvin N Janal; Van P Thompson; Niek J Opdam; Yu Zhang
Journal:  Dent Mater       Date:  2016-01-08       Impact factor: 5.304

4.  Wear Characteristics of Dental Ceramic CAD/CAM Materials Opposing Various Dental Composite Resins.

Authors:  Bora Gwon; Eun-Bin Bae; Jin-Ju Lee; Won-Tak Cho; Hyun-Young Bae; Jae-Won Choi; Jung-Bo Huh
Journal:  Materials (Basel)       Date:  2019-06-06       Impact factor: 3.623

5.  Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns.

Authors:  Jae-Won Choi; Ik-Hyun Bae; Tae-Hwan Noh; Sung-Won Ju; Tae-Kyoung Lee; Jin-Soo Ahn; Tae-Sung Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

6.  Effects of air abrasion with alumina or glass beads on surface characteristics of CAD/CAM composite materials and the bond strength of resin cements.

Authors:  Arao Nobuaki; Yoshida Keiichi; Sawase Takashi
Journal:  J Appl Oral Sci       Date:  2015 Nov-Dec       Impact factor: 2.698

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.