Intraoperative unidirectional intra-aortic balloon pumping in the management of left ventricular power failure.

D Bregman, E N Parodi, R N Edie, F O Bowman, K Reemtsma, J R Malm.   

Abstract

Unidirectional intra-aortic balloon pumping (IABP) was applied to 28 adult patients undergoing open-heart surgery over a 35 month period. The patients were divided into three groups according to the temporal sequence of initiating IABP. Group A consisted of 4 patients who were in a low output state or in cardiogenic shock prior to study. All patients survived cardiac catheterization and surgery, and 3 (75 per cent) were long-term survivors. Group B included 15 patients who could not be weaned from cardiopulmonary bypass with the usual supportive measures. Twelve patients (80 per cent) were weaned from bypass with IABP, and 11 (73 per cent) were discharged from the hospital. Group C was composed of 9 patients who manifested a low cardiac output syndrome within the first 24 hours following surgery. IABP was initiated in the recovery room. Six patients (67 per cent) were discharged. The total experience with these 28 patients therefore includes 24 patients (86 per cent) who were weaned from IABP, 20 (71 per cent) who were discharged, and 18 (64 per cent) who were long-term survivors. The present criteria for the use of IABP in the cardiac surgical patient are defined.

Entities:  

Mesh:

Year:  1975        PMID: 1186280

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  8 in total

1.  Microprocessor control of intra-aortic balloon pumping.

Authors:  E Philippe; J W Clark; A Lande; J R Ellis
Journal:  Ann Biomed Eng       Date:  1980       Impact factor: 3.934

2.  Experience with intra-aortic balloon pumping and the first clinical application of an ellipsoid left ventricular assist device.

Authors:  W Fasching; F Unger; M Deutsch; E Horcher; F Stellwag; H Thoma; R Weisskirchner; E Wolner; K Polzer; J Navratil
Journal:  World J Surg       Date:  1978-11       Impact factor: 3.352

3.  Automatic control of a series-parallel mechanical circulatory assist system in severe uni- or biventricular failure.

Authors:  J W Clark; E Philippe; R Peterson; A Lande; J R Ellis
Journal:  Ann Biomed Eng       Date:  1980       Impact factor: 3.934

4.  Influence of vascular parameters on the effectiveness of intra-aortic balloon pumping: a model study.

Authors:  C Kao; W J Ohley
Journal:  Med Biol Eng Comput       Date:  1982-09       Impact factor: 2.602

5.  Stabilisation of medically refractory ventricular arrhythmia by intra-aortic balloon counterpulsation.

Authors:  G D Fotopoulos; M J Mason; S Walker; N S Jepson; D J Patel; A G Mitchell; C D Ilsley; V E Paul
Journal:  Heart       Date:  1999-07       Impact factor: 5.994

6.  Intra-aortic balloon pump: a perspective.

Authors:  J E McGee
Journal:  J Natl Med Assoc       Date:  1981-09       Impact factor: 1.798

7.  Use of intra-aortic balloon pumping (IABP) in clinical cardiac surgery and management of patients with IABP.

Authors:  H Watanabe; W D Johnson; R T Shore; K L Kayser
Journal:  Jpn J Surg       Date:  1978-12

8.  RIGHT AND LEFT VENTRICULAR HEMODYNAMIC INDICES AS PREDICTORS OF THE NEED FOR AND OUTCOME OF POST-CARDIOTOMY MECHANICAL INTRAAORTIC BALLOON PUMP SUPPORT.

Authors:  T M Fuhrman; J T Sturm; D A Holub; M G McGee; J M Fuqua; C H Edmonds; C Bedderman; C W Hibbs; S R Igo; S K Edelman; J C Norman
Journal:  Cardiovasc Dis       Date:  1979-09