Literature DB >> 11857664

Development of a non-invasive strategy to classify bladder outlet obstruction in male patients with LUTS.

J J M Pel1, J L H R Bosch, J H M Blom, A A B Lycklama à Nijeholt, R van Mastrigt.   

Abstract

To diagnose bladder outlet obstruction in male patients with lower urinary tract symptoms (LUTS), it is necessary to measure the bladder pressure via a transurethral (or suprapubic) catheter. This procedure incurs some risk of urinary tract infection and urethral trauma and is sometimes painful to the patient. We developed an external condom catheter to measure non-invasively the bladder pressure and developed a strategy to classify bladder outlet obstruction (BOO) based on this measurement. Seventy-five patients with a wide range of urological diagnoses underwent a pressure-flow study followed by a non-invasive study. We tested five different strategies to classify the patients using the provisional International Continence Society (ICS) method for definition of obstruction as the gold standard. Leakage of the external catheter occurred in eight (40%) of the first 20 tested patients. In the remaining 55 patients, only five (9%) of the measurements failed because of leakage. Of the 75 patients, 56 were successfully tested non-invasively. According to the ICS nomogram, the PFS showed that 22 of these patients were non-obstructed, 12 patients were equivocal, and 22 patients were obstructed. Ten of these 56 patients strained, and we found that the relatively high abdominal pressures in these patients were not reflected in the externally measured bladder pressure. Of the remaining 46 patients, 12 of 13 non-obstructed patients and 30 of 33 combined equivocal and obstructed patients could be correctly classified. We developed a simple, non-invasive classification strategy to identify BOO in those male patients who did not strain during voiding. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11857664     DOI: 10.1002/nau.10046

Source DB:  PubMed          Journal:  Neurourol Urodyn        ISSN: 0733-2467            Impact factor:   2.696


  15 in total

1.  A flow rate cut-off value as a criterion for the accurate non-invasive measurement of bladder pressure using a condom-type catheter.

Authors:  Johan J M Pel; Ron van Mastrigt
Journal:  Urol Res       Date:  2003-05-14

Review 2.  The role of invasive and non-invasive urodynamics in male voiding lower urinary tract symptoms.

Authors:  Brian A Parsons; Elizabeth Bright; Ahmed M Shaban; Anne Whitehouse; Marcus J Drake
Journal:  World J Urol       Date:  2009-11-15       Impact factor: 4.226

3.  Urine flow acceleration is superior to Qmax in diagnosing BOO in patients with BPH.

Authors:  Jian-Guo Wen; Lin-Gang Cui; Yi-Dong Li; Xiao-Ping Shang; Wen Zhu; Rui-Li Zhang; Qing-Jun Meng; Sheng-Jun Zhang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-08-01

4.  Pressure flow urodynamic studies: the gold standard for diagnosing bladder outlet obstruction.

Authors:  Victor W Nitti
Journal:  Rev Urol       Date:  2005

5.  [Overactive bladder--which diagnosis investigations are necessary before initiating primary treatment?].

Authors:  B Schönberger
Journal:  Urologe A       Date:  2003-04-25       Impact factor: 0.639

6.  A novel intraurethral device diagnostic index to classify bladder outlet obstruction in men with lower urinary tract symptoms.

Authors:  Leonardo O Reis; Guilherme C Barreiro; Alessandro Prudente; Cleide M Silva; José W M Bassani; Carlos A L D'Ancona
Journal:  Adv Urol       Date:  2008-12-25

7.  Non-invasive evaluation of bladder outlet obstruction in men suspected of benign prostatic hyperplasia: usefulness of the d index.

Authors:  Françoise A Valentini; Pierre P Nelson; Philippe E Zimmern
Journal:  Curr Urol       Date:  2012-12-21

8.  New Diagnostics for Male Lower Urinary Tract Symptoms.

Authors:  Natalie R Swavely; John E Speich; Lynn Stothers; Adam P Klausner
Journal:  Curr Bladder Dysfunct Rep       Date:  2019-05-03

9.  The evidence for urodynamic investigation of patients with symptoms of urinary incontinence.

Authors:  Peter F Rosier
Journal:  F1000Prime Rep       Date:  2013-03-04

10.  Development and application of the condom catheter method for non-invasive measurement of bladder pressure.

Authors:  R van Mastrigt; J J M Pel; J W N C Huang Foen Chung; S de Zeeuw
Journal:  Indian J Urol       Date:  2009-01