Literature DB >> 11857441

Surface characteristics and structure of anodic oxide films containing Ca and P on a titanium implant material.

Xiaolong Zhu1, Joo L Ong, Sukyoung Kim, Kyohan Kim.   

Abstract

An anodic oxide film that formed on titanium with a mixture of beta-glycerophosphate sodium (beta-GP) and calcium acetate was investigated. The anodic oxide had interconnected pores (ca. 1-2 microm in diameter) and intermediate roughness (0.60-1.50 microm). In addition, it contained a mixture of amorphous, anatase, and rutile oxides. With an increase in the anodizing voltage and/or concentration of calcium incorporated into the oxide, the degree of oxide crystallinity increased. However, with an increase in the concentration of beta-GP, the degree of oxide crystallinity decreased. It was concluded that the surface roughness, oxide crystallinity, and surface composition of the anodic oxide were dependent on the voltage, current density, and concentration of the electrolyte. It was also concluded that the anodized surface could be optimized for maximum osseointegration. Copyright 2002 John Wiley & Sons, Inc. J Biomed Mater Res 60: 333--338, 2002; DOI 10.1002/jbm.10105

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11857441     DOI: 10.1002/jbm.10105

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  8 in total

1.  In vitro biocompatibility of orthodontic miniscrews with human gingival fibroblast and SAOS-2 osteoblast cultures.

Authors:  Hannah Finke; Bernd Koos; Helge Fischer-Brandies; Martha Es-Souni
Journal:  J Orofac Orthop       Date:  2018-07-16       Impact factor: 1.938

2.  Osseointegration improvement by plasma electrolytic oxidation of modified titanium alloys surfaces.

Authors:  Mónica Echeverry-Rendón; Oscar Galvis; David Quintero Giraldo; Juan Pavón; José Luis López-Lacomba; Emilio Jiménez-Piqué; Marc Anglada; Sara M Robledo; Juan G Castaño; Félix Echeverría
Journal:  J Mater Sci Mater Med       Date:  2015-01-29       Impact factor: 3.896

3.  Osseointegration of bioactive microarc oxidized amorphous phase/TiO2 nanocrystals composited coatings on titanium after implantation into rabbit tibia.

Authors:  Rui Zhou; Daqing Wei; Haoyue Yang; Su Cheng; Wei Feng; Baoqiang Li; Yaming Wang; Dechang Jia; Yu Zhou
Journal:  J Mater Sci Mater Med       Date:  2014-01-31       Impact factor: 3.896

4.  A study of the physical, chemical and biological properties of TiO2 coatings produced by micro-arc oxidation in a Ca-P-based electrolyte.

Authors:  Amanda dos Santos; Joyce R Araujo; Sandra M Landi; Alexei Kuznetsov; José M Granjeiro; Lidia Ágata de Sena; Carlos Alberto Achete
Journal:  J Mater Sci Mater Med       Date:  2014-04-08       Impact factor: 3.896

5.  Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits.

Authors:  Jung-Woo Koh; Jae-Ho Yang; Jung-Suk Han; Jai-Bong Lee; Sung-Hun Kim
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

6.  Effect of surface anodization on stability of orthodontic microimplant.

Authors:  Sanket Karmarker; Wonjae Yu; Hee-Moon Kyung
Journal:  Korean J Orthod       Date:  2012-02-27       Impact factor: 1.372

7.  Reality of dental implant surface modification: a short literature review.

Authors:  In-Sung Yeo
Journal:  Open Biomed Eng J       Date:  2014-10-31

8.  Rapid structural regulation, apatite-inducing mechanism and in vivo investigation of microwave-assisted hydrothermally treated titania coating.

Authors:  Lin Chen; Junyu Ren; Narisu Hu; Qing Du; Daqing Wei
Journal:  RSC Adv       Date:  2021-02-12       Impact factor: 3.361

  8 in total