Fracture characteristics of carbon fibre, ceramic and non-palladium endodontic post systems at monotonously increasing loads.

P Ottl1, L Hahn, H Ch Lauer, M Fay.   

Abstract

A carbon fibre post system, three non-palladium and one palladium metal post systems, two ceramic post systems, and a metal post system with a ceramic core were studied in vitro. The control group consisted of root-filled test teeth without posts. The test teeth were identical artificial roots of an upper central incisor made from a posterior composite whose module of elasticity was similar to that of natural dentine. All posts were cemented in the roots using Panavia 21 TC. Subsequently, standardized full crowns were cemented onto all roots. On a universal testing machine, the test teeth were loaded palatally at monotonously increasing loads until root fracture. The highest mean fracture loads were found for the carbon fibre post system (312.5 +/- 58.8 N). The fracture load of non-palladium metal posts (242.3-300.4 N) did not differ significantly from that of the Perma-dor post (265.9 N), which does contain palladium. Values of 300.3 +/- 89.3 N (aluminium oxide ceramics) and 193.5 +/-57.0 N (zirconia ceramics) were found for the ceramic posts. The control group exhibited a fracture load of 228.8 +/- 35.7 N. The mean distance between the vestibular end of the fracture gap and the point of force application was between 10.1 +/- 2.3 and 14.7 +/- 1.2 mm.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11856397     DOI: 10.1046/j.1365-2842.2002.00852.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  9 in total

1.  Comparative evaluation of fracture resistance of various post systems using different luting agents under tangential loading.

Authors:  Rajnish Aggarwal; Swati Gupta; Amrit Tandan; Narendra Kumar Gupta; Ravi Dwivedi; Renu Aggarwal
Journal:  J Oral Biol Craniofac Res       Date:  2013-04-17

2.  A comparative evaluation of fracture resistance of endodontically treated teeth restored with different post core systems - an in-vitro study.

Authors:  Chetana S Makade; Ganesh K Meshram; Manjusha Warhadpande; Pravinkumar G Patil
Journal:  J Adv Prosthodont       Date:  2011-06-30       Impact factor: 1.904

3.  Evaluation of the effect of different ferrule designs on fracture resistance of maxillary incisors restored with bonded posts and cores.

Authors:  Z Mahdavi Izadi; E Jalalian; A Eyvaz Ziaee; L Zamani; B Javanshir
Journal:  J Dent (Tehran)       Date:  2010-09-30

4.  Evaluation of different post lengths' effect on fracture resistance of a glass fiber post system.

Authors:  Necdet Adanir; Sema Belli
Journal:  Eur J Dent       Date:  2008-01

5.  Influence of Different Post Luting Cements on the Fracture Strength of Endodontically Treated Teeth: An In Vitro Study.

Authors:  Abdulaziz Samran; Mohammed O Najjar; Ahlam Samran; Majed Al-Akhali; Sadeq A Al-Maweri; Mutlu Özcan
Journal:  Eur Endod J       Date:  2018-07-19

6.  Stress Distribution on Root Dentin Analogous to Natural Teeth with Various Retentive Channels Design on the Face of the Root with Minimal or No Coronal Tooth Structure: A Finite Element Analysis.

Authors:  Shoeb Yakub Shaikh; Shahnawaz Mulani; Safia Shoeb Shaikh
Journal:  Contemp Clin Dent       Date:  2018 Oct-Dec

7.  Structural integrity of extracted teeth restored using three different post-and-core systems: An in vitro comparative study.

Authors:  Lamyia Anweigi; Rawan Noah; Lujain Alessa; Ebtissam Al-Madi; Alhanoof Aldegheishem
Journal:  Saudi Dent J       Date:  2020-01-30

8.  The effect of amount of lost tooth structure and restorative technique on fracture resistance of endodontically treated premolars.

Authors:  Mahshid Mohammadi Bassir; Akram Labibzadeh; Fatemeh Mollaverdi
Journal:  J Conserv Dent       Date:  2013-09

9.  Effect of cyclic loading on fracture strength of endodontically treated teeth restored with conventional and esthetic posts.

Authors:  Anuar Antônio Xible; Rudys Rodolfo de Jesus Tavarez; Carlos Dos Reis Pereira de Araujo; Paulo César Rodrigues Conti; Wellington Cardoso Bonachella
Journal:  J Appl Oral Sci       Date:  2006-08       Impact factor: 2.698

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.