Literature DB >> 11854719

Device migration after endoluminal abdominal aortic aneurysm repair: analysis of 113 cases with a minimum follow-up period of 2 years.

Piergiorgio Cao1, Fabio Verzini, Simona Zannetti, Paola De Rango, Gianbattista Parlani, Luciano Lupattelli, Agostino Maselli.   

Abstract

PURPOSE: Device migration (DM) has been shown to cause late failure after endoluminal abdominal aortic aneurysm (AAA) repair. To establish the incidence rate and the predictive factors of distal migration of the proximal portion of the endograft, computed tomographic (CT) scans performed at different time intervals during follow-up examination of 113 patients were reviewed. PATIENTS AND METHODS: Between April 1997 and March 1999, 148 patients underwent endoluminal AAA repair with a modular endograft with infrarenal fixation (Medtronic-AVE AneuRx, Santa Rosa, Calif) at our unit. CT scans performed at 1, 6, and 12 months after surgery and yearly thereafter were prospectively stored in a computer imaging database. Patient demographics, risk factors, operative details, and follow-up events were prospectively collected. No patients were lost to follow-up examination. Twelve patients died within 2 years of surgery, four patients underwent immediate conversion to open repair, and adequate CT measurements were not feasible in 19 cases, which left 113 patients available for a minimum 2-year assessment and 418 CT scan results reviewed. Two vascular surgeons, blinded to patient identity and history with tested interobserver agreement (kappa = 0.64), separately reviewed axial reconstructions of CT scans. DM was defined as changes of 10 mm or more in the distance between the lower renal artery and the first visible portion of the endograft at follow-up examination. Ten possible independent predictors of DM were analyzed with multivariate Cox proportional hazards regression model.
RESULTS: One AAA rupture, which was successfully treated, occurred at a mean follow-up period of 28 months (range, 24 to 46 months). Seventeen patients (15%) showed DM. Eight patients (47%) with DM underwent reintervention: a proximal cuff was positioned in six patients and late conversion to open repair was performed in two patients. Of the 10 variables analyzed with Cox proportional hazards regression model, AAA neck enlargement of more than 10% after endoluminal repair (hazard ratio, 7.3; confidence interval, 1.8 to 29.2; P =.004) and preoperative AAA diameter of 55 mm or more (hazard ratio, 4.5; confidence interval, 1.2 to 16.7; P =.02) were positive independent predictors of DM. The probability of DM at 36 months was 27% according to life table analysis.
CONCLUSION: DM occurred in a significant portion of our patients, yet aggressive follow-up examination and a high reintervention rate prevented aneurysm-related death. According to our data, dilatation of the infrarenal aortic neck is an important factor that contributes to the distal migration of stent grafts, and patients with large aneurysms are at high risk for DM.

Entities:  

Mesh:

Year:  2002        PMID: 11854719     DOI: 10.1067/mva.2002.120045

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  11 in total

1.  Evaluation of the proximal aortic neck enlargement following endovascular repair of abdominal aortic aneurysm: 3-years experience.

Authors:  Vinicio Napoli; Savino G Sardella; Irene Bargellini; Pasquale Petruzzi; Roberto Cioni; Claudio Vignali; Mauro Ferrari; Carlo Bartolozzi
Journal:  Eur Radiol       Date:  2003-04-12       Impact factor: 5.315

2.  Effect of curvature on displacement forces acting on aortic endografts: a 3-dimensional computational analysis.

Authors:  C Alberto Figueroa; Charles A Taylor; Victoria Yeh; Allen J Chiou; Christopher K Zarins
Journal:  J Endovasc Ther       Date:  2009-06       Impact factor: 3.487

3.  Treatment of complications following endovascular repair of abdominal aortic aneurysms.

Authors:  William Grande; S William Stavropoulos
Journal:  Semin Intervent Radiol       Date:  2006-06       Impact factor: 1.513

4.  Comparison of Endovascular Stent Grafts for Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries.

Authors:  Dominique B Buck; Peter A Soden; Sarah E Deery; Sara L Zettervall; Klaas H J Ultee; Bruce E Landon; A James O'Malley; Marc L Schermerhorn
Journal:  Ann Vasc Surg       Date:  2017-09-08       Impact factor: 1.466

5.  Endovascular stent graft repair of abdominal and thoracic aortic aneurysms: a ten-year experience with 817 patients.

Authors:  Michael L Marin; Larry H Hollier; Sharif H Ellozy; David Spielvogel; Harold Mitty; Randall Griepp; Robert A Lookstein; Alfio Carroccio; Nicholas J Morrissey; Victoria J Teodorescu; Tikva S Jacobs; Michael E Minor; Claudie M Sheahan; Kristina Chae; Juliana Oak; Andrew Cha
Journal:  Ann Surg       Date:  2003-10       Impact factor: 12.969

6.  Postoperative "Chimney" for Unintentional Renal Artery Occlusion after EVAR.

Authors:  Marco Franchin; Federico Fontana; Filippo Piacentino; Matteo Tozzi; Gabriele Piffaretti
Journal:  Case Rep Vasc Med       Date:  2014-11-16

Review 7.  Diagnostic imaging methods applied in long-term surveillance after EVAR. Will computed tomography angiography be replaced by other methods?

Authors:  Karolina Stefaniak; Michal Stanisic; Marcin Gabriel; Grzegorz Oszkinis
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-02-11       Impact factor: 1.426

8.  Stent-Graft Relining in a Patient with Acute Aortic Aneurysm and a Completely Migrated Endograft.

Authors:  Jayandiran Pillai; Ceyhan Yazicioglu; Mahad Omar; Martin G Veller
Journal:  Braz J Cardiovasc Surg       Date:  2017 Nov-Dec

9.  Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones.

Authors:  Ying Guan; Lu Wang; Jing Lin; Martin W King
Journal:  Materials (Basel)       Date:  2016-08-05       Impact factor: 3.623

10.  Novel open technique for repair of endograft migration.

Authors:  Yue Gao; Dimitrios Miserlis; Nitin Garg; Iraklis Pipinos
Journal:  J Vasc Surg Cases Innov Tech       Date:  2019-04-28
View more