Literature DB >> 11853252

Scanning acoustic microscopy study of human cortical and trabecular bone.

S Bumrerraj1, J L Katz.   

Abstract

Scanning acoustic microscopy (SAM) has been used in the burst mode to study the properties of human cortical and trabecular bone. An Olympus UH3 SAM (Olympus Co., Tokyo, Japan) was used with a 400 MHz burst mode lens (120 degrees aperture, nominal lateral resolution 2.5 microm). The human cortical bone was from the midshaft of a femur from a 60+ male cadaver; the trabecular bone specimens were obtained from the distal femoral condyles of another 60+ human male cadaver. Elastic moduli for both trabecular and cortical bone were obtained by means of a series of calibration curves correlating SAM gray levels of known materials with their elastic moduli; specimens included: polypropylene, PMMA, Teflon, aluminum, Pyrex glass, titanium, and stainless steel. Values obtained by this method are in good agreement with those obtained by nanoindentation techniques. The three critical findings earlier by Katz and Meunier were observed here as well in both the cortical and trabecular bone samples.

Entities:  

Mesh:

Year:  2001        PMID: 11853252     DOI: 10.1114/1.1424908

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  6 in total

1.  A micromechanical elastic property study of trabecular bone in the human mandible.

Authors:  Tsutomu Nomura; J Lawrence Katz; Michael P Powers; Chikara Saito
Journal:  J Mater Sci Mater Med       Date:  2007-04       Impact factor: 3.896

2.  Multiscale mechanics of hierarchical structure/property relationships in calcified tissues and tissue/material interfaces.

Authors:  J Lawrence Katz; Anil Misra; Paulette Spencer; Yong Wang; Sauwanan Bumrerraj; Tsutomu Nomura; Steven J Eppell; Massood Tabib-Azar
Journal:  Mater Sci Eng A Struct Mater       Date:  2007-04       Impact factor: 5.234

Review 3.  New laboratory tools in the assessment of bone quality.

Authors:  D Chappard; M F Baslé; E Legrand; M Audran
Journal:  Osteoporos Int       Date:  2011-02-24       Impact factor: 4.507

4.  Functional apparent moduli as predictors of oral implant osseointegration dynamics.

Authors:  Po-Chun Chang; Yang-Jo Seol; Noboru Kikuchi; Steven A Goldstein; William V Giannobile
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2010-07       Impact factor: 3.368

Review 5.  Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-16       Impact factor: 2.725

Review 6.  The effect of the microscopic and nanoscale structure on bone fragility.

Authors:  M E Ruppel; L M Miller; D B Burr
Journal:  Osteoporos Int       Date:  2008-03-04       Impact factor: 4.507

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.