Phosphate kinetics during hemodialysis: Evidence for biphasic regulation.

Elaine M Spalding1, Paul W Chamney, Ken Farrington.   

Abstract

BACKGROUND: Hyperphosphatemia in the hemodialysis population is ubiquitous, but phosphate kinetics during hemodialysis is poorly understood.
METHODS: Twenty-nine hemodialysis patients each received one long and one short dialysis, equivalent in terms of urea clearance. Phosphate concentrations were measured during each treatment and for one hour thereafter. A new model of phosphate kinetics was developed and implemented in VisSim. This model characterized additional processes involved in phosphate kinetics explaining the departure of the measured data from a standard two-pool model.
RESULTS: Pre-dialysis phosphate concentrations were similar in long and short dialysis groups. Post-dialysis phosphate concentrations in long dialysis were higher than in short dialysis (P < 0.02) despite removal of a greater mass of phosphate (P < 0.001). In both long and short dialysis serum phosphate concentrations initially fell in accordance with two-pool kinetics, but thereafter plateaued or increased despite continuing phosphate removal. Implementation of an additional regulatory mechanism such that a third pool liberates phosphate to maintain an intrinsic target concentration (1.18 +/- 0.06 mmol/L; 95% confidence intervals, CI) explained the data in 24% of treatments. The further addition of a fourth pool hysteresis element triggered by critically low phosphate levels (0.80 +/- 0.07 mmol/L, CI) yielded an excellent correlation with the observed data in the remaining 76% of treatments (cumulative standard deviation 0.027 +/- 0.004 mmol/L, CI). The critically low concentration correlated with pre-dialysis phosphate levels (r=0.67, P < 0.0001).
CONCLUSION: Modeling of phosphate kinetics during hemodialysis implies regulation involving up to four phosphate pools. The accuracy of this model suggests that the proposed mechanisms have physiological validity.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11849409     DOI: 10.1046/j.1523-1755.2002.00146.x

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  25 in total

Review 1.  Hyperphosphataemia in renal failure: causes, consequences and current management.

Authors:  Fouad Albaaj; Alastair Hutchison
Journal:  Drugs       Date:  2003       Impact factor: 9.546

2.  Staying on target with continuous dialysis.

Authors:  Sevag Demirjian; William H Fissell
Journal:  Clin J Am Soc Nephrol       Date:  2014-12-23       Impact factor: 8.237

3.  A two-pool kinetic model predicts phosphate concentrations during and shortly following a conventional (three times weekly) hemodialysis session.

Authors:  John T Daugirdas
Journal:  Nephrol Dial Transplant       Date:  2018-01-01       Impact factor: 5.992

4.  Hemodiafiltration beneficially affects QT interval duration and dispersion compared to hemodialysis.

Authors:  Kitti Barta; Árpád Czifra; Csaba Kun; Alida Páll; Julianna Kulcsár; György Paragh; István Lőrincz; Tamás János Padra; Anupam Agarwal; Abolfazl Zarjou; Zarjou Abolfazl; József Balla; Zoltán Szabó
Journal:  Clin Exp Nephrol       Date:  2014-03-04       Impact factor: 2.801

5.  A new technique for low-volume continuous sampling of spent dialysate: a validation study.

Authors:  Rafael Bueno Orcy; Maria Fernanda Antunes; Jean Pierre Oses; Maristela Böhlke
Journal:  J Artif Organs       Date:  2019-02-08       Impact factor: 1.731

6.  Kinetic model of phosphorus mobilization during and after short and conventional hemodialysis.

Authors:  Baris U Agar; Alp Akonur; Ying-Cheng Lo; Alfred K Cheung; John K Leypoldt
Journal:  Clin J Am Soc Nephrol       Date:  2011-10-27       Impact factor: 8.237

7.  Dialysis cannot be dosed.

Authors:  Timothy W Meyer; Tammy L Sirich; Thomas H Hostetter
Journal:  Semin Dial       Date:  2011-09-19       Impact factor: 3.455

8.  Short daily hemodialysis is associated with lower plasma FGF23 levels when compared with conventional hemodialysis.

Authors:  Joshua Zaritsky; Anjay Rastogi; George Fischmann; Jieshi Yan; Kenneth Kleinman; Georgina Chow; Barbara Gales; Isidro B Salusky; Katherine Wesseling-Perry
Journal:  Nephrol Dial Transplant       Date:  2013-09-05       Impact factor: 5.992

9.  Calcium and phosphate balance in adolescents on home nocturnal haemodialysis.

Authors:  Daljit K Hothi; Elizabeth Harvey; Elizabeth Piva; Laura Keating; Donna Secker; Denis F Geary
Journal:  Pediatr Nephrol       Date:  2006-04-01       Impact factor: 3.714

10.  Phosphate levels and blood pressure in incident hemodialysis patients: a longitudinal study.

Authors:  Cindy Xin Huang; Laura C Plantinga; Nancy E Fink; Michal L Melamed; Josef Coresh; Neil R Powe
Journal:  Adv Chronic Kidney Dis       Date:  2008-07       Impact factor: 3.620