Literature DB >> 11847621

The influence of the posterior cruciate ligament in the maintenance of joint line in primary total knee arthroplasty: a radiologic study.

M R Cope1, B S O'Brien, A M Nanu.   

Abstract

The aim of this study was to compare 2 total knee arthroplasty (TKA) designs radiologically to determine if a posterior cruciate ligament (PCL)-substituting design led to a built-in error of elevation of the joint line postoperatively. The restoration of the true joint line is a goal in primary TKA, although its effect on outcome has not been established fully. A total of 47 patients had 56 TKAs performed by 2 surgeons using either the Howmedica Kinemax Plus (Rutherford, NJ) PCL-retaining or PCL-substituting TKAs. The patients were randomized to receive one of these designs, and the height of the joint line was assessed radiographically preoperatively and postoperatively. The joint line position preoperatively averaged 2.2 cm from the tibial tuberosity and postoperatively averaged 2.4 cm (PCL substituting) and 2.5 cm (PCL sparing). No difference in the thickness of the polyethylene insert used was seen with either design. The theoretical elevation of the joint line that occurs with the sacrifice of the PCL was not found to occur radiologically.

Entities:  

Mesh:

Year:  2002        PMID: 11847621     DOI: 10.1054/arth.2002.29396

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  15 in total

1.  Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique.

Authors:  Lars Perlick; Holger Bäthis; Carsten Perlick; Christian Lüring; Markus Tingart; Joachim Grifka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-04-08       Impact factor: 4.342

2.  Comparison between two computer-assisted total knee arthroplasty: gap-balancing versus measured resection technique.

Authors:  Domenico Tigani; G Sabbioni; R Ben Ayad; M Filanti; N Rani; N Del Piccolo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-10       Impact factor: 4.342

3.  Joint line changes after primary total knee arthroplasty: navigated versus non-navigated.

Authors:  A Jawhar; V Shah; S Sohoni; H P Scharf
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-06-22       Impact factor: 4.342

4.  Joint line is well restored when navigation surgery is performed for total knee arthroplasty.

Authors:  A Ensini; F Catani; N Biasca; C Belvedere; S Giannini; A Leardini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-28       Impact factor: 4.342

5.  Gap balancing versus measured resection technique using a mobile-bearing prosthesis in computer-assisted surgery.

Authors:  G Sabbioni; N Rani; N Del Piccolo; R Ben Ayad; C Carubbi; D Tigani
Journal:  Musculoskelet Surg       Date:  2011-03-05

6.  Change in collateral ligament length and tibiofemoral movement following joint line variation in TKA.

Authors:  Kun-Jhih Lin; Hung-Wen Wei; Chang-Hung Huang; Yu-Liang Liu; Wen-Chuan Chen; Colin Joseph McClean; Cheng-Kung Cheng
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-30       Impact factor: 4.342

7.  Factors affecting the osteolysis around the components after posterior-stabilized total knee replacement arthroplasty.

Authors:  Chang Wan Kim; Seung Suk Seo; Jung Han Kim; Hyeong Joo Lee; Chang Rack Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

8.  The medial tibial joint line elevation over 5 mm restrained the improvement of knee extension angle in unicompartmental knee arthroplasty.

Authors:  Koji Takayama; Kazunari Ishida; Hirotsugu Muratsu; Yuichi Kuroda; Masanori Tsubosaka; Shingo Hashimoto; Shinya Hayashi; Takehiko Matsushita; Takahiro Niikura; Ryosuke Kuroda; Tomoyuki Matsumoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-09       Impact factor: 4.342

9.  Raising the Joint Line in TKA is Associated With Mid-flexion Laxity: A Study in Cadaver Knees.

Authors:  Thomas Luyckx; Hilde Vandenneucker; Lennart Scheys Ing; Evie Vereecke; Arnout Victor Ing; Jan Victor
Journal:  Clin Orthop Relat Res       Date:  2018-03       Impact factor: 4.176

10.  [Revision prosthetic of the knee joint. The influence of a navigation system on the alignment and reconstruction of the joint line].

Authors:  L Perlick; C Lüring; M Tingart; J Grifka; H Bäthis
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.