| Literature DB >> 11845893 |
Stacy B O'Blenes1, Christopher M Feindel.
Abstract
Coronary arteries with anomalous origin from the aorta can be at risk during aortic valve procedures. We report a case of origin of the circumflex and left coronary artery from the proximal right coronary artery in a patient with a bicuspid aortic valve and aortic root aneurysm. Attention to the anatomic relationship of the anomalous arteries to the aorta allowed safe aortic root replacement.Entities:
Mesh:
Year: 2002 PMID: 11845893 DOI: 10.1016/s0003-4975(01)03116-2