Literature DB >> 11845875

A biomechanical comparison of three sternotomy closure techniques.

David J Cohen1, Lanny V Griffin.   

Abstract

BACKGROUND: A biomechanical study of three sternotomy closure techniques (figure-of-eight stainless-steel wires, Pectofix Dynamic Sternal Fixation [DSF] stainless-steel plates, and figure-of-eight stainless-steel cables) was conducted to compare strength and stiffness variables in three clinically relevant loading modes (anterior-posterior shear, longitudinal shear, and lateral distraction).
METHODS: All tests were conducted on polyurethane foam sternal models that simulate the properties of cancellous bone. Each model was divided longitudinally and reconstructed using one of the sternotomy closure repair techniques. Tests were performed using a materials testing system that applies a continuously increasing amount of force in one direction to the model until it catastrophically breaks. A total of six trials of each fixation type in each of three test groups were prepared and tested, for a total of 54 tests. Strength and stiffness variables as well as a post-yield analysis of failure were evaluated.
RESULTS: Sternums repaired using the DSF plate system are a more rigid construct than sternums repaired using the stainless-steel wires or cables in the distraction and transverse shear modes and they are not significantly different from sternums repaired with wires or cables in the longitudinal shear mode. The DSF plate system offers a 25% improvement in resistance to failure (yield) compared to wires when a transverse shear force is applied to the model. The cable system had a higher resistance to failure than the wires in all modes although the differences were not statistically significant. Additionally, the DSF plate system provides substantial reduction of the implant's cutting into the sternal model under loading as evidenced by the post-yield displacement when compared with either cables or wires for the distraction and longitudinal shear modes. For the transverse shear mode, the cables or wires would completely fail at the load for which cutting begins for the DSF.
CONCLUSIONS: Both the DSF plate system and the stainless-steel cable system offer important advantages over figure-of-eight wire for sternal closure.

Entities:  

Mesh:

Year:  2002        PMID: 11845875     DOI: 10.1016/s0003-4975(01)03389-6

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  16 in total

1.  Absorbable sternal pins improve sternal closure stability within a small deviation.

Authors:  Hiroshi Koshiyama; Kenji Yamazaki
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-02-27

2.  Sternal Precautions: Is It Time for Change? Precautions versus Restrictions - A Review of Literature and Recommendations for Revision.

Authors:  Lawrence P Cahalin; Tanya Kinney Lapier; Donald K Shaw
Journal:  Cardiopulm Phys Ther J       Date:  2011-03

3.  Late complications of chest wall reconstruction: management of painful sternal nonunion.

Authors:  Kyle J Chepla; Christopher J Salgado; Cathy J Tang; Samir Mardini; Karen K Evans
Journal:  Semin Plast Surg       Date:  2011-02       Impact factor: 2.314

4.  Sternal closure after median sternotomy: a new technique using titanium hooks and wires applied parasternally.

Authors:  Eckehard Kilian; Helmut Mair; Bruno Reichart; Peter Lamm
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-02-28

5.  Prevention of sternal wound complications after sternotomy: results of a large prospective randomized multicentre trial.

Authors:  Michael Gorlitzer; Florian Wagner; Steffen Pfeiffer; Sandra Folkmann; Johann Meinhart; Theodor Fischlein; Hermann Reichenspurner; Martin Grabenwoeger
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-06-11

6.  Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery.

Authors:  You Na Oh; Keong Jun Ha; Joon Bum Kim; Sung-Ho Jung; Suk Jung Choo; Cheol Hyun Chung; Jae Won Lee
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2015-08-05

7.  Use of new cannulated screws for primary sternal closure in high risk patients for sternal dehiscence.

Authors:  Giuseppe De Cicco; Davide Tosi; Roberto Crisci; Andrea Bortolami; Tommaso Maria Aquino; Aldo Prencipe; Gerardo Di Matteo; Stefano Benussi
Journal:  J Thorac Dis       Date:  2019-11       Impact factor: 2.895

8.  Prevention of sternal dehiscence with the sternum external fixation (Stern-E-Fix) corset--randomized trial in 750 patients.

Authors:  Lachmandath S Tewarie; Ares K Menon; Nima Hatam; Andrea Amerini; Ajay K Moza; Rüdiger Autschbach; Andreas Goetzenich
Journal:  J Cardiothorac Surg       Date:  2012-09-09       Impact factor: 1.637

9.  Sternal plating for primary and secondary sternal closure; can it improve sternal stability?

Authors:  Hosam Fawzy; Nasser Alhodaib; C David Mazer; Alana Harrington; David Latter; Daniel Bonneau; Lee Errett; James Mahoney
Journal:  J Cardiothorac Surg       Date:  2009-05-07       Impact factor: 1.637

10.  Fatigue testing of three peristernal median sternotomy closure techniques.

Authors:  Cameron Wangsgard; David J Cohen; Lanny V Griffin
Journal:  J Cardiothorac Surg       Date:  2008-09-24       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.