Literature DB >> 11844195

Uterine artery Doppler and placental volume in the first trimester in the prediction of pregnancy complications.

K Schuchter1, M Metzenbauer, E Hafner, K Philipp.   

Abstract

OBJECTIVE: To evaluate placental volume and uterine artery Doppler in the first trimester in the prediction of pregnancies that subsequently develop pre-eclampsia, pregnancy-induced hypertension, preterm placental abruption or fetal growth restriction.
METHODS: In 380 singleton pregnancies attending our center for nuchal translucency screening at 11-14 weeks of gestation, Doppler assessment of both uterine arteries was carried out for measurement of the pulsatility index and the mean pulsatility index of the two vessels was calculated. In addition, three-dimensional ultrasound was used to obtain images for subsequent measurement of placental volume. The 90th centile of the uterine artery mean pulsatility index and the 10th centile of the placental volume for crown-rump length (placental quotient) were calculated. These cut-offs were used for the prediction of pregnancy complications.
RESULTS: Complications occurred in 36 (9.5%) of the 380 pregnancies, including 31 cases of fetal growth restriction, two of pregnancy-induced hypertension and abruption, two of pregnancy-induced hypertension, and one of abruption. The uterine artery mean pulsatility index was > or =90th centile in 38 (10%) pregnancies and this group contained nine (25%) of those that developed complications. The placental quotient was < or =10th centile in 39 (10%) pregnancies and this group contained eight (22%) of those that developed complications. In eight (2%) pregnancies the uterine artery mean pulsatility index was > or =90th centile and the placental quotient was < or =10th centile and this group contained six (17%) of those that developed complications.
CONCLUSION: The combination of placental volume measurement and uterine artery Doppler in the first trimester may identify women at risk for subsequent development of pregnancy complications.

Entities:  

Mesh:

Year:  2001        PMID: 11844195     DOI: 10.1046/j.0960-7692.2001.00596.x

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  10 in total

1.  First-trimester placental ultrasound and maternal serum markers as predictors of small-for-gestational-age infants.

Authors:  Nadav Schwartz; Mary D Sammel; Rita Leite; Samuel Parry
Journal:  Am J Obstet Gynecol       Date:  2014-03-05       Impact factor: 8.661

Review 2.  Abnormal Placentation Associated with Infertility as a Marker of Overall Health.

Authors:  Lauren W Sundheimer; Margareta D Pisarska
Journal:  Semin Reprod Med       Date:  2017-06-28       Impact factor: 1.303

3.  Defective placentation syndromes and autism spectrum disorder in the offspring: population-based cohort and sibling-controlled studies.

Authors:  Eduardo Villamor; Ezra S Susser; Sven Cnattingius
Journal:  Eur J Epidemiol       Date:  2022-07-05       Impact factor: 12.434

4.  Mode of conception does not affect fetal or placental growth parameters or ratios in early gestation or at delivery.

Authors:  Lauren W Sundheimer; Jessica L Chan; Rae Buttle; Rosemarie DiPentino; Olivia Muramoto; Kerlly Castellano; Erica T Wang; John Williams; Margareta D Pisarska
Journal:  J Assist Reprod Genet       Date:  2018-04-10       Impact factor: 3.412

5.  Reproducibility of 3-Dimensional Ultrasound Measurements of Placental Volume at Gestational Ages 11 - 14 Weeks.

Authors:  M L Larsen; K V Naver; M M Kjaer; F S Jorgensen; L Nilas
Journal:  Facts Views Vis Obgyn       Date:  2015-12-28

6.  Larger First-Trimester Placental Volumetric Parameters Are Associated With Lower Pressure and More Flow-Mediated Vasodilation of the Fetoplacental Vasculature After Delivery.

Authors:  Emilie Hitzerd; Igna F Reijnders; Annemarie G M G J Mulders; Anton H J Koning; Irwin K M Reiss; A H Jan Danser; Régine P M Steegers-Theunissen; Sinno H P Simons; Maria P H Koster
Journal:  Front Physiol       Date:  2020-01-24       Impact factor: 4.566

Review 7.  Insights into the role of placenta thickness as a predictive marker of perinatal outcome.

Authors:  Xiwen Sun; Jiayu Shen; Liquan Wang
Journal:  J Int Med Res       Date:  2021-02       Impact factor: 1.671

Review 8.  Placental Volume and Uterine Artery Doppler in Pregnancy Following In Vitro Fertilization: A Comprehensive Literature Review.

Authors:  Serena Resta; Gaia Scandella; Ilenia Mappa; Maria Elena Pietrolucci; Pavjola Maqina; Giuseppe Rizzo
Journal:  J Clin Med       Date:  2022-09-29       Impact factor: 4.964

9.  The influence of frozen-thawed and fresh embryo transfer on utero-placental (vascular) development: the Rotterdam Periconception cohort.

Authors:  Linette van Duijn; Melek Rousian; Igna F Reijnders; Sten P Willemsen; Esther B Baart; Joop S E Laven; Régine P M Steegers-Theunissen
Journal:  Hum Reprod       Date:  2021-07-19       Impact factor: 6.918

10.  Relationship between Plasma D-Dimer Concentration and Three-Dimensional Ultrasound Placental Volume in Women at Risk for Placental Vascular Diseases: A Monocentric Prospective Study.

Authors:  Cécile Fanget; Céline Chauleur; Amandine Stadler; Emilie Presles; Marie-Noëlle Varlet; Jean-Christophe Gris; Tiphaine Raia-Barjat
Journal:  PLoS One       Date:  2016-06-13       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.