Literature DB >> 11844029

Effect of length and diameter of tapered posts on the retention.

I Nergiz1, P Schmage, M Ozcan, U Platzer.   

Abstract

The force transmission of tapered unthreaded posts along the root has been reported to be homogenous but their retentive strength was found to be lower compared with those of parallel unthreaded or other kinds of threaded posts. The purpose of this in vitro study was to investigate the effect of length and diameter on the retentive strength of sandblasted tapered prefabricated titanium posts (Erlangen post system). Posts with constant taper angle but with three different lengths (9, 12, 15 mm) and apical diameters (0.5, 0.9, 1.1 mm) were cemented using zinc phosphate cement into the prepared and roughened post spaces of 90 intact anterior teeth. The post retention concerning length and diameter, being independent from each other, was measured by a tensile force test. The retentive strength was found to be proportional to the length as well as to the diameter of the posts. The mean minimum strength (181 +/- 14 N) recorded for the thinnest and shortest post was significantly lower than that of mean maximum strength (612 +/- 85 N) obtained from those of the thickest and longest post. Proportional bond strengths of the posts comprising their surface areas ranged between 6.8 and 7.9 N mm(-2) which were not significantly different between any group. The retention was effected strongly with the increase in the length (approximately 100%) than with the increase in the diameter (approximately 60%). Concerning the posts tested in this study, it is concluded that some caution should be exercised in the choice of post with appropriate length rather than diameter for the tooth concerned.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11844029     DOI: 10.1046/j.1365-2842.2002.00806.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  10 in total

1.  Can cement film thickness influence bond strength and fracture resistance of fiber reinforced composite posts?

Authors:  Alice Gonçalves Penelas; Valery Martins Piedade; Ana Carolina Oliveira da Silva Borges; Laiza Tatiana Poskus; Eduardo Moreira da Silva; José Guilherme Antunes Guimarães
Journal:  Clin Oral Investig       Date:  2015-08-29       Impact factor: 3.573

2.  Effect of post space preparation drills on the incidence of root dentin defects.

Authors:  Thaíse Ayres Bezerra Zuli; Orlando Aguirre Guedes; Gislaine Figueiredo Zarza Arguello Gonçalves; Aurélio Rosa da Silva Júnior; Álvaro Henrique Borges; Andreza Maria Fábio Aranha
Journal:  Restor Dent Endod       Date:  2020-10-16

3.  To evaluate and compare the effect of different Post Surface treatments on the Tensile Bond Strength between Fiber Posts and Composite Resin.

Authors:  Deepa Shori; Swapnil Pandey; Rajesh Kubde; Yogesh Rathod; Rahul Atara; Shravan Rathi
Journal:  J Int Oral Health       Date:  2013-10-26

4.  Fracture resistance of upper central incisors restored with different posts and cores.

Authors:  Maryam Rezaei Dastjerdi; Kamran Amirian Chaijan; Saeid Tavanafar
Journal:  Restor Dent Endod       Date:  2015-07-24

5.  Biomechanical Evaluation of a Tooth Restored with High Performance Polymer PEKK Post-Core System: A 3D Finite Element Analysis.

Authors:  Ki-Sun Lee; Joo-Hee Shin; Jong-Eun Kim; Jee-Hwan Kim; Won-Chang Lee; Sang-Wan Shin; Jeong-Yol Lee
Journal:  Biomed Res Int       Date:  2017-03-12       Impact factor: 3.411

6.  Evaluation of retention and fracture resistance of different fiber reinforced posts: An in vitro study.

Authors:  Varun Pruthi; Sangeeta Talwar; Ruchika Roongta Nawal; Preeti Jain Pruthi; Sarika Choudhary; Seema Yadav
Journal:  J Conserv Dent       Date:  2018 Mar-Apr

7.  Push-Out Bond Strength Assessment of Different Post Systems at Different Radicular Levels of Endodontically Treated Teeth.

Authors:  Valérie Kanzler Abdel Raouf; Julia Jockusch; Nadin Al-Haj Husain; Nataliya Dydyk; Mutlu Özcan
Journal:  Materials (Basel)       Date:  2022-07-24       Impact factor: 3.748

8.  In vitro evaluation of ferrule effect and depth of post insertion on fracture resistance of fiber posts.

Authors:  R Schiavetti; G Sannino
Journal:  Comput Math Methods Med       Date:  2012-12-02       Impact factor: 2.238

9.  Push-out bond strength of a fiber post system with two resin cements.

Authors:  Ramin Mosharraf; Alireza Haerian
Journal:  Dent Res J (Isfahan)       Date:  2011-12

10.  Effect of eugenol-containing sealer and post diameter on the retention of fiber reinforced composite posts.

Authors:  Alireza Izadi; Mohadese Azarsina; Shahin Kasraei
Journal:  J Conserv Dent       Date:  2013-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.