Comparison of five platforms for enumeration of residual leucocytes in leucoreduced blood components.

P F van der Meer1, J W Gratama, C J van Delden, R F Laport, W H Levering, J G Schrijver, M J Tiekstra, M Keeney, J de Wildt-Eggen.   

Abstract

The need for quality control of leucoreduction of blood products has led to the development of various methods to count low levels of residual leucocytes. We compared five platforms side-by-side: the Nageotte haemocytometer and four based on fluorescent staining of nuclei: two flowcytometers (Beckman Coulter, BD Biosciences) with methods based on counting beads, a volumetric flow cytometer (Partec) and the microvolumic fluorimeter ImagN2000 (BD Biosciences), all according to their manufacturers' recommended methods. Analysis of double-filtered red cell concentrates (RCCs) and platelet concentrates (PCs), spiked with various numbers of leucocytes, revealed good linearity for all methods over the range of 1.6-32.7 leucocytes/microl, all with r(2) > 0.99. At the rejection level of leucocyte-reduced blood components, i.e. 1 x 10(6) per unit corresponding with approximately 3.3 leucocytes/microl, the Nageotte haemocytometer had low accuracy (0% for RCCs, 56% for PCs), and was relatively imprecise [coefficient of variance (CV) of 34% and 30% respectively]. The Partec flow cytometer gave good results for RCCs (accuracy 67%, CV 22%), but not for PCs (accuracy 0%, CV 25%). The ImagN2000 had an accuracy of 44% for RCCs and 89% for PCs, but the precision was variable (CV 32% for RCCs, 15% for PCs). The best results were obtained with the Beckman Coulter (RCCs: accuracy 86%, CV 13%, PCs: accuracy 67%, CV 16%), and BD Biosciences platforms (RCCs: accuracy 100%, CV 10%; PCs: accuracy 89%, CV 11%). We conclude that, at the rejection level of 1 x 10(6) leucocytes per unit, the widely used Nageotte haemocytometer performs poorly in terms of inaccuracy and imprecision, and that both counting-bead-based, flow cytometric methods performed best.

Entities:  

Mesh:

Year:  2001        PMID: 11843833     DOI: 10.1046/j.1365-2141.2001.03154.x

Source DB:  PubMed          Journal:  Br J Haematol        ISSN: 0007-1048            Impact factor:   6.998


  4 in total

1.  A Time- and Compartment-Specific Activation of Lung Macrophages in Hypoxic Pulmonary Hypertension.

Authors:  Steven C Pugliese; Sushil Kumar; William J Janssen; Brian B Graham; Maria G Frid; Suzette R Riddle; Karim C El Kasmi; Kurt R Stenmark
Journal:  J Immunol       Date:  2017-05-12       Impact factor: 5.422

2.  Lipopolysaccharide is a direct agonist for platelet RNA splicing.

Authors:  Pavel N Shashkin; G Thomas Brown; Arundhati Ghosh; Gopal K Marathe; Thomas M McIntyre
Journal:  J Immunol       Date:  2008-09-01       Impact factor: 5.422

3.  Neutrophil extracellular traps in stored canine red blood cell units.

Authors:  Erin R McQuinn; Stephanie A Smith; Austin K Viall; Chong Wang; Dana N LeVine
Journal:  J Vet Intern Med       Date:  2020-09-03       Impact factor: 3.333

4.  Comparison of Flow Cytometric Methods for the Enumeration of Residual Leucocytes in Leucoreduced Blood Products: A Multicenter Study.

Authors:  Yang Zeng; Michelle Dabay; Virginia George; Shalini Seetharaman; Monika de Arruda Indig; Sharon Graminske; Nicole Kimpel; Anna Schmidt; Amanda Boerner; Sarai Paradiso; Tatyana Delman; Yunyao Li; Viktoriya Litvak; Farzad Oreizy; Angela Chen; Maryam Saleminik; Fred Mosqueda; Anna Lin; Kevin Judge
Journal:  Cytometry A       Date:  2018-01-18       Impact factor: 4.355

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.