Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis.

G Lonnemann1, L Sereni, H D Lemke, C Tetta.   

Abstract

Pyrogen permeability of the new highly permeable synthetic membrane polyethersulfone (DIAPES) was compared to polysulfone in vitro dialysis experiments with heparinized human donor blood in the blood compartment. After sterile dialysis for 5 min, dialysate was contaminated with a culture filtrate of Pseudomonas aeruginosa using high and moderate challenge doses (Limulus assay reactivity 20,000 EU/ml and 50 EU/ml, respectively). Whole blood samples were separated from the blood compartment during the sterile (5 min) and contaminated (60 min) phases of dialysis and incubated for 6 h at 37 degrees C. Blood samples were lysed, and interleukin-1beta and tumor necrosis factor alpha were measured by specific ELISAs. Moderate dialysate contamination (50 EU/ml) did not induce detectable cytokine production in whole blood. High challenge dose (20,000 EU/ml) induced whole blood interleukin-1beta and tumor necrosis factor alpha production in the blood compartment, which was higher with DIAPES than with polysulfone after 30 min. After 60 min, membrane-dependent differences were no longer detectable. Pyrogen concentrations in the dialysate decreased with time indicating adsorption of cytokine-inducing substances to the dialyzer membrane. Pyrogens adsorbed to dialyzer membranes were resuspended during recirculation of sterile phosphate-buffered saline in the dialysate compartment and retained cytokine-inducing activity as seen from whole blood incubation experiments. DIAPES and polysulfone adsorbed pyrogens in the presence of whole blood. Pyrogen adsorption to the membrane polymer and/or to the protein coat on the membrane prevented the passage of pyrogens in the presence of moderately contaminated dialysate. High grade dialysate contamination caused breakthrough of pyrogens into the blood with DIAPES and polysulfone. In order to reduce the risk of a dialysis-dependent inflammatory response, dialysate of high bacteriological quality (ultrapure dialysate) should be mandatory.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11843762     DOI: 10.1046/j.1525-1594.2001.06832.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Performance of polysulfone membrane dialyzers and dialysate flow pattern.

Authors:  Ayumu Nakashima; Satoshi Ogata; Shigehiro Doi; Michihiro Yamahira; Satoe Naraki; Norihisa Takasugi; Toshifumi Ohmoto; Takafumi Ito; Takao Masaki; Noriaki Yorioka
Journal:  Clin Exp Nephrol       Date:  2006-09       Impact factor: 2.801

2.  Assessment of the association between increasing membrane pore size and endotoxin permeability using a novel experimental dialysis simulation set-up.

Authors:  Eva Schepers; Griet Glorieux; Sunny Eloot; Michael Hulko; Adriana Boschetti-de-Fierro; Werner Beck; Bernd Krause; Wim Van Biesen
Journal:  BMC Nephrol       Date:  2018-01-05       Impact factor: 2.388

3.  Validation and applicability of an alternative method for dialysis water and dialysate quality analysis.

Authors:  Gabriela Corrêa Carvalho; Adriana Bugno; Adriana Aparecida Buzzo Almodovar; Fernando Pontes de Lima E Silva; Terezinha de Jesus Andreoli Pinto
Journal:  J Bras Nefrol       Date:  2020-04-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.