Literature DB >> 11843497

The CarboMedics prosthetic heart valve: experience with 1,084 implants.

Francesco Santini1, Gianluca Casali, Francesca Viscardi, Alessandro Favaro, Giovanni Battista Luciani, Samuele Pentiricci, Mario Lusini, Andrea Rossi, Alessandro Mazzucco.   

Abstract

BACKGROUND AND AIM OF THE STUDY: The study aim was to evaluate our clinical experience with the CarboMedics heart valve prosthesis.
METHODS: Between October 1991 and December 2000, 942 consecutive patients (514 males, 428 females; mean age 58+/-11 years; range: 6-78 years) underwent mechanical valve implantation with the CarboMedics prosthesis. Preoperatively, 47% of patients were in NYHA class III and 22% in class IV; in addition, 134 patients (14.2%) had undergone a previous cardiac operation. Aortic valve replacement (AVR) was performed in 469 patients (49.8%), mitral valve replacement (MVR) in 330 (35.0%), double valve replacement (DVR) in 142 (15.1%), and isolated tricuspid valve replacement (TVR) in one patient. Eighty-eight patients (9.3%) underwent associated myocardial revascularization. Mean cardiopulmonary bypass and aortic cross-clamp times for the entire group were 107+/-39 min and 74+/-24 min, respectively.
RESULTS: Overall early mortality was 2.3% (6/469 AVR, 1.2%; 12/330 MVR, 3.6%; 4/142 DVR, 2.8%). Late mortality was 3.1% (n = 29; including 17 cardiac deaths (10 were valve-related). Mean follow up was 66+/-31 months (range: 1-109 months), and was 98% complete yielding a total follow up of 4959 years. Actuarial survival at five years for the entire group was 89.3+/-1.6% (AVR 91.1%, MVR 86.4%, DVR 90.5%). Thromboembolism occurred in 26 patients (2.8%, 0.52%/pt-year) and major hemorrhagic events in 20 (2.1%, 0.4%/pt-year). Nine patients (0.9%) required a reoperation, in three cases (0.3%) after Staphylococcus epidermidis-mediated endocarditis. No structural deterioration occurred. Among 891 survivors, 94% of the patients are currently in NYHA classes I or II (p <0.05).
CONCLUSION: This study confirmed the safety and reliability of the CarboMedics mechanical valve prosthesis, even in old age groups. This bileaflet prosthesis showed no structural deterioration, and a low incidence of overall complications.

Entities:  

Mesh:

Year:  2002        PMID: 11843497

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  2 in total

1.  Complete detachment of an aortic valve prosthesis 10 years after implantation.

Authors:  P Grubwieser; M Pavlic; D Hoefer; W Rabl
Journal:  Int J Legal Med       Date:  2003-10-22       Impact factor: 2.686

2.  Special report: 26-year durability of a bioprosthesis implanted in a 21-year-old patient.

Authors:  Torulv Holst; Josef Reichert; Peter Haldenwang; Vadim Moustafine; Matthias Bechtel; Justus Strauch; Stephan Knipp
Journal:  Thorac Cardiovasc Surg Rep       Date:  2014-02-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.