Literature DB >> 11842026

Measurement of hemodynamics in human carotid artery using ultrasound and computational fluid dynamics.

Mirian J Starmans-Kool1, Alice V Stanton, Shunzhi Zhao, X Yun Xu, Simon A M Thom, Alun D Hughes.   

Abstract

The objective of the study was to investigate the feasibility of using computational fluid dynamic modeling (CFD) with noninvasive ultrasound measurements to determine time-variant three-dimensional (3D) carotid arterial hemodynamics in humans in vivo. The effects of hyperoxia and hypoxic hypercapnia on carotid artery local hemodynamics were examined by use of this approach. Six normotensive volunteers followed a double-blind randomized crossover design. Blood pressure, heart rate, and carotid blood flow were measured while subjects breathed normal air, a mixture of 5% CO(2) and 15% O(2) (hypoxic hypercapnia), and 100% O(2) (hyperoxia). Carotid artery geometry was reconstructed on the basis of B-mode ultrasound images by using purpose-built image processing software. Time-variant 3D carotid hemodynamics were estimated by using finite volume-based CFD. Systemic blood pressure was not significantly affected by hyperoxia or hypoxic hypercapnia, but heart rate decreased significantly with hyperoxia. There was an increase in diastolic flow velocity in the external carotid artery after hypoxic hypercapnia, but otherwise carotid blood flow velocities did not change significantly. Compared with normal air, hyperoxic conditions were associated with a decrease in the width of the region of flow separation in the external carotid artery. During hyperoxia, there was also an increase in the minimum and a decrease in maximum shear stress in the bifurcation and hence a reduction in cyclic variation in shear stress. Hypoxic hypercapnia was associated with a reduced duration of flow separation in the external carotid artery and an increase in the minimum shear stress without affecting the cyclic variation in shear stress. This study demonstrates the feasibility of using noninvasive ultrasound techniques in conjunction with CFD to describe time-variant 3D hemodynamics in the human carotid arterial bifurcation in vivo.

Entities:  

Mesh:

Year:  2002        PMID: 11842026     DOI: 10.1152/japplphysiol.00171.2001

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  3 in total

1.  Patient-specific computational fluid dynamics: structured mesh generation from coronary angiography.

Authors:  Gianluca De Santis; Peter Mortier; Matthieu De Beule; Patrick Segers; Pascal Verdonck; Benedict Verhegghe
Journal:  Med Biol Eng Comput       Date:  2010-02-17       Impact factor: 2.602

2.  Halting the effects of flow enhancement with effective intermittent zeugmatographic encoding (HEFEWEIZEN) in SSFP.

Authors:  Jamal J Derakhshan; Mark A Griswold; Jeffrey L Sunshine; Jeffrey L Duerk
Journal:  J Magn Reson Imaging       Date:  2009-05       Impact factor: 4.813

3.  Fluid structure interaction versus rigid-wall approach in the study of the symptomatic stenosed carotid artery: Importance of wall compliance and resilience of loose connective tissue.

Authors:  Daniel Jodko; Mateusz Jeckowski; Zbigniew Tyfa
Journal:  Int J Numer Method Biomed Eng       Date:  2022-07-10       Impact factor: 2.648

  3 in total