Literature DB >> 11839407

Automatic evaluation of arterial diameter variation from vascular echographic images.

F Beux1, S Carmassi, M V Salvetti, L Ghiadoni, Y Huang, S Taddei, A Salvetti.   

Abstract

An automatic procedure for accurate arterial diameter evaluation from B-mode images obtained by diagnostic ultrasound systems is presented. It is used for measuring brachial artery dilation following reactive hyperemia induced by forearm ischemia, which is an appropriate parameter to study endothelial function in humans. B-mode images obtained from the diagnostic ultrasound system are acquired on a personal computer as grey intensity fields (pixels). A completely automatic algorithm is then applied and the artery walls are identified by two discrete sets of points. Artery diameter is evaluated by parabolic least-square approximation. The accuracy and extensive range of applicability of the diameter evaluation procedure were demonstrated both by preliminary analytic test cases and in vivo analyses. Reproducibility of the diameter estimate was assessed by in vivo measurements. The proposed procedure permits fast and accurate analysis of large amounts of data, because it requires no action by the operator. It thus represents a valuable tool for assessment of endothelium-dependent vasodilation, especially in large, multicentric clinical trials.

Entities:  

Mesh:

Year:  2001        PMID: 11839407     DOI: 10.1016/s0301-5629(01)00450-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  Evaluation of an algorithm for arterial lumen diameter measurements by means of ultrasound.

Authors:  Magnus Cinthio; Tomas Jansson; Anders Eriksson; Asa Rydén Ahlgren; Hans W Persson; Kjell Lindström
Journal:  Med Biol Eng Comput       Date:  2010-07-16       Impact factor: 2.602

2.  Vascular adaptations to hypobaric hypoxic training in postmenopausal women.

Authors:  Masato Nishiwaki; Ryoko Kawakami; Kazuto Saito; Hiroyuki Tamaki; Hiroaki Takekura; Futoshi Ogita
Journal:  J Physiol Sci       Date:  2010-12-22       Impact factor: 2.781

3.  Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound.

Authors:  Theodore W Cary; Courtney B Reamer; Laith R Sultan; Emile R Mohler; Chandra M Sehgal
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

4.  Intra-rater reliability of leg blood flow during dynamic exercise using Doppler ultrasound.

Authors:  Sachin B Amin; Hendrik Mugele; Florian E Dobler; Kyohei Marume; Jonathan P Moore; Justin S Lawley
Journal:  Physiol Rep       Date:  2021-10

5.  Model-based analysis of flow-mediated dilation and intima-media thickness.

Authors:  G Bartoli; G Menegaz; M Lisi; G Di Stolfo; S Dragoni; T Gori
Journal:  Int J Biomed Imaging       Date:  2009-04-06

6.  Tissue Doppler imaging of carotid plaque wall motion: a pilot study.

Authors:  Kumar V Ramnarine; Tim Hartshorne; Yvonne Sensier; May Naylor; Joanne Walker; A Ross Naylor; Ronney B Panerai; David H Evans
Journal:  Cardiovasc Ultrasound       Date:  2003-12-19       Impact factor: 2.062

7.  Sequentially based analysis versus image based analysis of Intima Media Thickness in common carotid arteries studies - do major IMT studies underestimate the true relations for cardio- and cerebrovascular risk?

Authors:  M Sandrock; J Hansel; J Schulze; D Schmitz; A Niess; H Burkhardt; A Schmidt-Trucksaess
Journal:  Cardiovasc Ultrasound       Date:  2008-06-20       Impact factor: 2.062

8.  Relationship between Circulating PCSK9 and Markers of Subclinical Atherosclerosis-The IMPROVE Study.

Authors:  Daniela Coggi; Beatrice Frigerio; Alice Bonomi; Massimiliano Ruscica; Nicola Ferri; Daniela Sansaro; Alessio Ravani; Palma Ferrante; Manuela Damigella; Fabrizio Veglia; Nicolò Capra; Maria Giovanna Lupo; Chiara Macchi; Kai Savonen; Angela Silveira; Sudhir Kurl; Philippe Giral; Matteo Pirro; Rona Juliette Strawbridge; Bruna Gigante; Andries Jan Smit; Elena Tremoli; Mauro Amato; Damiano Baldassarre
Journal:  Biomedicines       Date:  2021-07-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.