Validity of in vitro tests on aqueous spray pumps as surrogates for nasal deposition.

Julie D Suman1, Beth L Laube, Ta-Chun Lin, Guillaume Brouet, Richard Dalby.   

Abstract

PURPOSE: To determine whether deposition pattern is related to in vitro measurements of droplet size, plume geometry, and spray pattern between two different nasal spray pumps believed to have different performance characteristics.
METHODS: Ten healthy volunteers inhaled radiolabeled saline from two different spray pumps (pump A and pump B). Deposition pattern was quantified from lateral views of the nose by gamma scintigraphy, expressed as the ratio of anterior to posterior (I:O) and superior to inferior (U:L) deposition. Droplet size was determined by Malvern Mastersizer S. Spray patterns were determined at 2.5 and 5 cm from the tip of the spray nozzle. Two-dimensional images of the emitted plume were captured by high-speed still photography.
RESULTS: There were no significant differences in I:O or U:L ratios for pump A compared to pump B, indicating no significant differences in deposition pattern. The volume diameters, Dv10 and Dv50, were not statistically different for pump A compared to pump B. There was a significant difference in Dv90 between pump A and pump B, (86.9 +/- 5.8 microm and 77.4 +/- 2.4 microm. respectively; P < 0.001). The ratio of the longest to shortest diameter for the spray pattern with pump A was 1.26 +/- 0.06 at 2.5 cm and 1.44 +/- 0.08 at 5 cm. The ratio for pump B was 1.13 +/- 0.03 at 2.5 cm and 1.19 +/- 0.05 at 5 cm. Ratios at both heights were statistically different for pump A compared to pump B (P < 0.00002 and P < 0.000001, respectively) Plume geometry analysis indicated statistical differences in both the width (17.0 +/- 0.97 vs. 18.5 +/- 0.56 cm, respectively: p<0.001) and the maximum length of the plumes (46.0 +/- 1.83 vs. 53.1 +/- 4.88 cm, respectively; p < .002). The differences in velocity of the plume and spray angle between the two pumps were not statistically different. CONCLUSIONS. Certain in vitro tests detected performance differences between the two pumps. However, these differences did not translate into different deposition patterns in vivo.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11837692     DOI: 10.1023/a:1013643912335

Source DB:  PubMed          Journal:  Pharm Res        ISSN: 0724-8741            Impact factor:   4.200


  11 in total

1.  Nasal delivery systems and their effect on deposition and absorption.

Authors: 
Journal:  Adv Drug Deliv Rev       Date:  1998-01-05       Impact factor: 15.470

2.  Commentary on the FDA draft guidance for bioequivalence studies for nasal aerosols and nasal sprays for local action: an industry view.

Authors:  L I Harrison
Journal:  J Clin Pharmacol       Date:  2000-07       Impact factor: 3.126

3.  Model of disposition of drugs administered into the human nasal cavity.

Authors:  I Gonda; E Gipps
Journal:  Pharm Res       Date:  1990-01       Impact factor: 4.200

4.  Deposition pattern of nasal sprays in man.

Authors:  S P Newman; F Morén; S W Clarke
Journal:  Rhinology       Date:  1988-06       Impact factor: 3.681

Review 5.  Deposition of aerosol in the respiratory tract.

Authors:  J D Brain; P A Valberg
Journal:  Am Rev Respir Dis       Date:  1979-12

6.  The importance of particle size in response to inhaled bronchodilators.

Authors:  P J Rees; T J Clark; F Morén
Journal:  Eur J Respir Dis Suppl       Date:  1982

Review 7.  Inhaled aerosols: lung deposition and clinical applications.

Authors:  S P Newman; J E Agnew; D Pavia; S W Clarke
Journal:  Clin Phys Physiol Meas       Date:  1982-02

8.  Intranasal administration of peptides: nasal deposition, biological response, and absorption of desmopressin.

Authors:  A S Harris; I M Nilsson; Z G Wagner; U Alkner
Journal:  J Pharm Sci       Date:  1986-11       Impact factor: 3.534

9.  Alveolar targeting of aerosol pentamidine. Toward a rational delivery system.

Authors:  A K Simonds; S P Newman; M A Johnson; N Talaee; C A Lee; S W Clarke
Journal:  Am Rev Respir Dis       Date:  1990-04

10.  Effect of aerosol particle size on bronchodilatation with nebulised terbutaline in asthmatic subjects.

Authors:  M M Clay; D Pavia; S W Clarke
Journal:  Thorax       Date:  1986-05       Impact factor: 9.139

View more
  11 in total

1.  Septoplasty and decongestant improve distribution of nasal spray.

Authors:  Jiaoping Mi; Yunping Fan; Shaoyan Feng; Wentong Xia; Jingqing Wang; Huabin Li
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2011-12-16

2.  A Computational Study of Nasal Spray Deposition Pattern in Four Ethnic Groups.

Authors:  Jarrod A Keeler; Aniruddha Patki; Charles R Woodard; Dennis O Frank-Ito
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2015-08-13       Impact factor: 2.849

3.  The effect of formulation variables and breathing patterns on the site of nasal deposition in an anatomically correct model.

Authors:  Yang Guo; Beth Laube; Richard Dalby
Journal:  Pharm Res       Date:  2005-08-16       Impact factor: 4.200

4.  Assessment of nasal spray deposition pattern in a silicone human nose model using a color-based method.

Authors:  Vipra Kundoor; Richard N Dalby
Journal:  Pharm Res       Date:  2009-11-10       Impact factor: 4.200

Review 5.  Non-impactor-based methods for sizing of aerosols emitted from orally inhaled and nasal drug products (OINDPs).

Authors:  Jolyon Mitchell; Richard Bauer; Svetlana Lyapustina; Terrence Tougas; Volker Glaab
Journal:  AAPS PharmSciTech       Date:  2011-07-22       Impact factor: 3.246

Review 6.  Mechanisms of pharmaceutical aerosol deposition in the respiratory tract.

Authors:  Yung Sung Cheng
Journal:  AAPS PharmSciTech       Date:  2014-02-22       Impact factor: 3.246

7.  Visualization and Quantification of Nasal and Olfactory Deposition in a Sectional Adult Nasal Airway Cast.

Authors:  Jinxiang Xi; Jiayao Eddie Yuan; Yu Zhang; Dannielle Nevorski; Zhaoxuan Wang; Yue Zhou
Journal:  Pharm Res       Date:  2016-03-04       Impact factor: 4.200

8.  Deviated nasal septum hinders intranasal sprays: a computer simulation study.

Authors:  D O Frank; J S Kimbell; D Cannon; S S Pawar; J S Rhee
Journal:  Rhinology       Date:  2012-09       Impact factor: 3.681

9.  Computed intranasal spray penetration: comparisons before and after nasal surgery.

Authors:  Dennis O Frank; Julia S Kimbell; Daniel Cannon; John S Rhee
Journal:  Int Forum Allergy Rhinol       Date:  2012-08-27       Impact factor: 3.858

10.  Analytical challenges and regulatory requirements for nasal drug products in europe and the u.s.

Authors:  Sabrina Trows; Klaus Wuchner; Rene Spycher; Hartwig Steckel
Journal:  Pharmaceutics       Date:  2014-04-11       Impact factor: 6.321

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.