Literature DB >> 11837612

Haemoglobin oxygenation of a two-layer tissue-simulating phantom from time-resolved reflectance: effect of top layer thickness.

Robert J Hunter1, Michael S Patterson, Thomas J Farrell, Joseph E Hayward.   

Abstract

A dual wavelength time-resolved reflectance system was developed for monitoring haemoglobin saturation noninvasively. At each wavelength, the time-resolved reflectance data were fitted to a diffusion model of light propagation in a homogeneous, semi-infinite medium to yield the absolute scattering and absorption coefficients. The absorption coefficients were then used to calculate haemoglobin saturation. A two-layer phantom containing human erythrocytes in a scattering solution in the bottom layer was used to study system performance under more realistic conditions. The top layer was chosen to simulate either skin or fat and the oxygenation of the bottom layer, which corresponded to muscle, was controlled. The thickness of the fat layer was varied from 1.5 to 10 mm to investigate the effects of increasing the top layer thickness. These results, obtained with the simple diffusion model, were compared with simultaneous measurements of oxygenation made directly in the bottom layer. Errors in estimating haemoglobin saturation with this method ranged from 5-11% depending on the thickness of the top layer and its optical properties.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11837612     DOI: 10.1088/0031-9155/47/2/302

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

Review 1.  Criteria for the design of tissue-mimicking phantoms for the standardization of biophotonic instrumentation.

Authors:  Lina Hacker; Heidrun Wabnitz; Antonio Pifferi; T Joshua Pfefer; Brian W Pogue; Sarah E Bohndiek
Journal:  Nat Biomed Eng       Date:  2022-05-27       Impact factor: 25.671

2.  Broadband continuous-wave technique to measure baseline values and changes in the tissue chromophore concentrations.

Authors:  Hadi Zabihi Yeganeh; Vladislav Toronov; Jonathan T Elliott; Mamadou Diop; Ting-Yim Lee; Keith St Lawrence
Journal:  Biomed Opt Express       Date:  2012-10-09       Impact factor: 3.732

Review 3.  Time-Resolved Diffuse Optical Spectroscopy and Imaging Using Solid-State Detectors: Characteristics, Present Status, and Research Challenges.

Authors:  Mrwan Alayed; M Jamal Deen
Journal:  Sensors (Basel)       Date:  2017-09-14       Impact factor: 3.576

Review 4.  Feature Extraction and Classification Methods for Hybrid fNIRS-EEG Brain-Computer Interfaces.

Authors:  Keum-Shik Hong; M Jawad Khan; Melissa J Hong
Journal:  Front Hum Neurosci       Date:  2018-06-28       Impact factor: 3.169

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.