Literature DB >> 11833683

The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length.

Ashraf ElAyouti1, Roland Weiger, Claus Löst.   

Abstract

The aim of this in vitro study was to evaluate the ability of the Root ZX device to avoid instrumentation beyond the apical foramen in premolars after conventional working length radiography. Thirty extracted premolars with 43 root canals were subjected to radiographic and electronic working length determination. Radiographic working length determination resulted in overestimation in 51% of the root canals, although the measuring file tip was located to be 0 to 2 mm short of the radiographic apex. Electronic working length measurements with the Root ZX reduced the percentage of overestimation to 21%. In 6 root canals (14%), both radiographic and electronic working length measurements led to overestimation. It is concluded that complementing radiographic working length determination with electronic apex locator measurements may help to avoid overestimation beyond the apical foramen in premolars.

Entities:  

Mesh:

Year:  2002        PMID: 11833683     DOI: 10.1097/00004770-200202000-00017

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  25 in total

1.  Accuracy of two different apex locators in primary teeth with and without root resorption.

Authors:  Haluk Bodur; Mesut Odabaş; Ozlem Tulunoğlu; Ali Cemal Tinaz
Journal:  Clin Oral Investig       Date:  2007-11-20       Impact factor: 3.573

2.  The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics.

Authors:  Bart Vandenberghe; Marius Bud; Asti Sutanto; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2009-05-19       Impact factor: 3.573

3.  Formulating a regression equation for determination of working length in primary molars using apex locators: a clinical study.

Authors:  A Dandempally; R Muppa; M K Duddu; P Bhupatiraju; S Nallanchakrava
Journal:  Eur Arch Paediatr Dent       Date:  2013-06-18

4.  Towards a bimodal proximity sensor for in situ neurovascular bundle detection during dental implant surgery.

Authors:  Jessie R Weber; François Baribeau; Paul Grenier; Frédéric Emond; Sylvain Dubois; François Duchesne; Marc Girard; Timothy Pope; Pascal Gallant; Ozzy Mermut; Hassan Ghaderi Moghadam
Journal:  Biomed Opt Express       Date:  2013-12-02       Impact factor: 3.732

5.  In vivo assessment of the impedance ratio method used in electronic foramen locators.

Authors:  Marcos V H Rambo; Humberto R Gamba; Gustavo B Borba; Joaquim M Maia; Carlos A S Ramos
Journal:  Biomed Eng Online       Date:  2010-09-06       Impact factor: 2.819

6.  Predetermination of root canal lengths in molar teeth: A comparison between radiovisiography and two-dimensional and three-dimensional measurements using cone-beam computed tomography.

Authors:  Annil Dhingra; Charu Dayal; Amteshwar Singh; Neetika Bhardwaj
Journal:  Indian J Dent       Date:  2015 Oct-Dec

7.  Healing of an extensive periradicular lesion subsequent to a proper endodontic treatment of a mandibular first premolar with complex anatomy.

Authors:  Hengameh Ashraf; Payam Paymanpour; Maryam Mojtahed Bidabadi; Reihaneh Hajrezai
Journal:  Case Rep Dent       Date:  2013-12-08

8.  A comparative evaluation of electronic and radiographic determination of root canal length in primary teeth: An in vitro study.

Authors:  Iyer Satishkumar Krishnan; Sheela Sreedharan
Journal:  Contemp Clin Dent       Date:  2012-10

9.  Comparison between two methods of working length determination and its effect on radiographic extent of root canal filling: a clinical study [ISRCTN71486641].

Authors:  L Smadi
Journal:  BMC Oral Health       Date:  2006-02-11       Impact factor: 2.757

10.  An In Vitro Comparison of Propex II Apex Locator to Standard Radiographic Method.

Authors:  Kalyan Vinayak Chakravarthy Pishipati
Journal:  Iran Endod J       Date:  2013-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.