Literature DB >> 11833680

The deterioration of rotary nickel-titanium files under controlled conditions.

Timothy A Svec1, John M Powers.   

Abstract

It has been shown that rotary nickel-titanium files cannot be used indefinitely. Researchers and clinicians have not been able to agree on how many times a file can be used before being discarded, except if a file has fractured or become visibly distorted. This study used ISO size 20 files of 0.04 taper in the curved canals of extracted mandibular molars. The canals had been previously instrumented to an ISO size 15 with stainless steel hand files. The irrigant used during rotary and hand instrumentation was Glyde. The rotary files were closely examined with scanning electron microscopy before use to detect any defects. They were then reexamined after each of five uses to document deterioration. An electric handpiece was configured to rotate at 150 rpm and secured to the testing device, which also held the extracted tooth. The testing device controlled the load at 8 N, the depth of penetration for each canal and the rate of penetration (12 mm/min). Used instruments demonstrated surface fatigue wear and cracking. Torsional moment at failure was determined on a torsiometer for used and new instruments. Data (n = 10) were analyzed by analysis of variance. The torsional moment for used and new instruments was not affected by use (p = 0.25).

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11833680     DOI: 10.1097/00004770-200202000-00014

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  4 in total

1.  Cyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro sem analysis.

Authors:  Pallavi Reddy Y; Kavita S; C V Subbarao
Journal:  J Clin Diagn Res       Date:  2014-02-03

2.  Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization.

Authors:  S Shahi; H Mokhtari; S Rahimi; V Shiezadeh; H Ashasi; M Abdolrahimi; M Foroughreyhani
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

3.  Comparative evaluation of surface changes in four Ni-Ti instruments with successive uses - An SEM study.

Authors:  N Subha; Vimal K Sikri
Journal:  J Conserv Dent       Date:  2011-07

4.  Comparative Evaluation of Physical Surface Changes and Incidence of Separation in Rotary Nickel-Titanium Instruments: An in Vitro SEM Study.

Authors:  Rudra Kaul; Riyaz Farooq; Vibhuti Kaul; Shafayat Ullah Khateeb; Aamir Rashid Purra; Roopali Mahajan
Journal:  Iran Endod J       Date:  2014-07-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.