Comparative evaluation of intraocular pressure changes subsequent to insertion of laryngeal mask airway and endotracheal tube.

B Ghai1, A Sharma, S Akhtar.   

Abstract

AIMS: To evaluate the intraocular pressure and haemodynamic changes subsequent to insertion of laryngeal mask airway and endotracheal tube. SUBJECTS AND METHODS: The study was conducted in 50 adult patients. A standard general anaesthesia was administered to all the patients. After 3 minutes of induction of anaesthesia baseline measurements of heart rate, non-invasive blood pressure and intraocular pressure were taken following which patients were divided into two groups: laryngeal mask airway was inserted in group 1 and tracheal tube in group 2. These measurements were repeated at 15-30 second, every minute thereafter up to 5 minutes after airway instrumentation.
RESULTS: A statistically significant rise in heart rate, systolic blood pressure, diastolic blood pressure and intraocular pressure was seen in both the groups subsequent to insertion of laryngeal mask airway or endotracheal tube. Mean maximum increase was statistically more after endotracheal intubation than after laryngeal mask airway insertion. The duration of statistically significant pressure responses was also longer after endotracheal intubation.
CONCLUSION: Laryngeal mask airway is an acceptable alternative technique for ocular surgeries, offering advantages in terms of intraocular pressure and cardiovascular stability compared to tracheal intubation.

Entities:  

Mesh:

Year:  2001        PMID: 11832619

Source DB:  PubMed          Journal:  J Postgrad Med        ISSN: 0022-3859            Impact factor:   1.476


  5 in total

Review 1.  Effect of Laryngeal Mask Airway Insertion on Intraocular Pressure Response: Systematic Review and Meta-Analysis.

Authors:  Mohammed Suleiman Obsa; Zewde Zema Kanche; Robera Olana Fite; Tilahun Saol Tura; Bulcha Guye Adema; Aseb Arba Kinfe; Melkamu Worku Kercho; Kebreab Paulos Chanko; Getahun Molla Shanka; Atkuregn Alemayehu Lencha; Gedion Asnake Azeze; Lolemo Kelbiso Hanfore; Nefsu Awoke Adulo; Blen Kassahun Dessu; Getahun Dendir Wolde; Shimelash Bitew Workie
Journal:  Anesthesiol Res Pract       Date:  2020-07-09

2.  A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery.

Authors:  Mohsen Ziyaeifard; Rasoul Azarfarin; Gholamreza Massoumi
Journal:  J Res Med Sci       Date:  2012-06       Impact factor: 1.852

3.  A comparative study of four combinations of anesthetic drugs for assessing the intraocular pressure changes during gynaecological laparoscopic procedures.

Authors:  Malti Agrawal; Vijay Dureja; Ananda Prakash Verma; Lakhwinder Singh Kang
Journal:  Anesth Essays Res       Date:  2013 Sep-Dec

4.  Effect of Laryngeal Mask Air Way Insertion versus Endotracheal Intubation over Hemodynamic Responses in Pediatrics Patient Who Underwent Ophthalmic Surgery at Menelik II Hospital, Addis Ababa: A Prospective Observational Study Design.

Authors:  Mohammed Suleiman Obsa; Azeb Lencha Sholla; Betelhem Girma Baraki; Getahun Dendir Welde; Temesgen Bati Gelgelu; Melese Meleku Kuruche
Journal:  Anesthesiol Res Pract       Date:  2020-06-01

5.  The effects of desflurane and sevoflurane on the intraocular pressure associated with endotracheal intubation in pediatric ophthalmic surgery.

Authors:  Jong Taek Park; Hyun Kyo Lim; Kyu-Yong Jang; Dea Ja Um
Journal:  Korean J Anesthesiol       Date:  2013-02-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.