Literature DB >> 1183259

Dynamic changes of cerebrospinal fluid in upright and recumbent shunted experimental animals.

S Yamada, T B Ducker, P L Perot.   

Abstract

The effect of positional change on intracranial CSF pressure, valve flow rates and atrial pressures were studied in 40 experimental dogs. The flow rate with a 30 to 60 mm H2O Holter valve changed from the recumbent to the head-up position: during the first minute it increased 2 1/2 times and then progressively decreased to become stabilized 20-30 min later at a value slightly lower than the head-up value. At the same time pressure dropped rapidly to -23 mm H2O and then slowly, during 30 min to -120 mm H2O. In dogs without a shunt the pressure drop was initially similar to that of shunted dogs but recovered to almost the initial positive pressure in 30 min. The flow rate from a reservoir to the atrium through a shunt system when changing to the head-up position showed a siphon effect. Atrial pressure does not change with positioning. The findings were similar with cisternal-peritoneal shunts. Flow rate, therefore, increase in the head-up position. Negative intracranial CSF pressure was due to a siphon effect through the shunt system.

Entities:  

Mesh:

Year:  1975        PMID: 1183259     DOI: 10.1159/000119566

Source DB:  PubMed          Journal:  Childs Brain        ISSN: 0302-2803


  7 in total

1.  CSF shunt physics: factors influencing inshunt CSF flow.

Authors:  C Kadowaki; M Hara; M Numoto; K Takeuchi; I Saito
Journal:  Childs Nerv Syst       Date:  1995-04       Impact factor: 1.475

2.  Ventriculo-subgaleal shunt: evaluation by computed tomography.

Authors:  A J Drapkin; M E Levine; W C Yang
Journal:  Acta Neurochir (Wien)       Date:  1980       Impact factor: 2.216

3.  Dynamic changes of cerebrospinal fluid shunt flow in patient's daily life.

Authors:  M Matsumae; T Murakami; M Ueda; Y Suzuki; O Sato
Journal:  Childs Nerv Syst       Date:  1987       Impact factor: 1.475

4.  Ventriculoperitoneal shunt for treatment of hydrocephalus in a French bulldog puppy.

Authors:  Jolene A Giacinti
Journal:  Can Vet J       Date:  2016-03       Impact factor: 1.008

5.  Is there a reasonable differential indication for different hydrocephalus shunt systems?

Authors:  H A Trost
Journal:  Childs Nerv Syst       Date:  1995-04       Impact factor: 1.475

6.  Comparison of 4D phase-contrast MRI flow measurements to computational fluid dynamics simulations of cerebrospinal fluid motion in the cervical spine.

Authors:  Theresia I Yiallourou; Jan Robert Kröger; Nikolaos Stergiopulos; David Maintz; Bryn A Martin; Alexander C Bunck
Journal:  PLoS One       Date:  2012-12-21       Impact factor: 3.240

7.  A novel rat model to study the role of intracranial pressure modulation on optic neuropathies.

Authors:  Uttio Roy Chowdhury; Bradley H Holman; Michael P Fautsch
Journal:  PLoS One       Date:  2013-12-18       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.