K L Weind1, C G Ellis, D R Boughner. 1. Heart Valve Laboratory, The John P. Robarts Research Institute, University of Western Ontario, London, Ontario, Canada.
Abstract
OBJECTIVES: The presence of a microvasculature within aortic cusps implies that tissue oxygen requirements exceed the amount deliverable by diffusion from the tissue surfaces alone. For the design of a successful tissue-engineered valve replacement, the effect of diffusion distance (tissue thickness) on oxygen delivery must be considered. We therefore examined in normal aortic valve cusps the relationship between the presence of microvessels and the tissue thickness. METHODS: Thirty porcine aortic valve cusps were excised and examined after cusp microvessels were pressure filled with a carbon particle solution. Cusp images were captured for stereographic vessel density analysis, and cusp thickness was determined with a radiographic technique. Histologic cross-sections were evaluated to determine vessel depth from the cusp surface. RESULTS: Cusp basal regions measured 0.69 to 0.86 mm in thickness, significantly thicker (P =.001) than the rest of the cusp, which measured 0.36 to 0.48 mm. In general a vascular bed was present when cusp thickness exceeded 0.5 mm, with a median value of 5.16 vessels/mm(3). CONCLUSIONS: From published values of arterial wall oxygen consumption and diffusivity, we predicted that the probable maximum oxygen diffusion distance for valve tissue would be about 0.2 mm. This was consistent with our physical findings, which implies that central tissue anoxia is avoided by the capillary bed. An avascular tissue-engineered valve metabolically similar to an aortic valve should therefore not exceed a thickness of approximately 0.40 mm.
OBJECTIVES: The presence of a microvasculature within aortic cusps implies that tissue oxygen requirements exceed the amount deliverable by diffusion from the tissue surfaces alone. For the design of a successful tissue-engineered valve replacement, the effect of diffusion distance (tissue thickness) on oxygen delivery must be considered. We therefore examined in normal aortic valve cusps the relationship between the presence of microvessels and the tissue thickness. METHODS: Thirty porcine aortic valve cusps were excised and examined after cusp microvessels were pressure filled with a carbon particle solution. Cusp images were captured for stereographic vessel density analysis, and cusp thickness was determined with a radiographic technique. Histologic cross-sections were evaluated to determine vessel depth from the cusp surface. RESULTS: Cusp basal regions measured 0.69 to 0.86 mm in thickness, significantly thicker (P =.001) than the rest of the cusp, which measured 0.36 to 0.48 mm. In general a vascular bed was present when cusp thickness exceeded 0.5 mm, with a median value of 5.16 vessels/mm(3). CONCLUSIONS: From published values of arterial wall oxygen consumption and diffusivity, we predicted that the probable maximum oxygen diffusion distance for valve tissue would be about 0.2 mm. This was consistent with our physical findings, which implies that central tissue anoxia is avoided by the capillary bed. An avascular tissue-engineered valve metabolically similar to an aortic valve should therefore not exceed a thickness of approximately 0.40 mm.
Authors: Matthew C Sapp; Varun K Krishnamurthy; Daniel S Puperi; Saheba Bhatnagar; Gabrielle Fatora; Neelesh Mutyala; K Jane Grande-Allen Journal: J R Soc Interface Date: 2016-12 Impact factor: 4.118
Authors: Julia C Swanson; Lauren R Davis; Koji Arata; Eleazar P Briones; Wolfgang Bothe; Akinobu Itoh; Neil B Ingels; D Craig Miller Journal: J Heart Valve Dis Date: 2009-09
Authors: C Alexander Arevalos; Amanda T Walborn; Amanda A Rupert; Jonathan M Berg; Elizabeth L Godfrey; Jacqueline M V Nguyen; K Jane Grande-Allen Journal: Microvasc Res Date: 2015-02-03 Impact factor: 3.514
Authors: Laura Mourino-Alvarez; Montserrat Baldan-Martin; Tamara Sastre-Oliva; Marta Martin-Lorenzo; Aroa Sanz Maroto; Nerea Corbacho-Alonso; Raul Rincon; Tatiana Martin-Rojas; Luis Fernando Lopez-Almodovar; Gloria Alvarez-Llamas; Fernando Vivanco; Luis Rodriguez Padial; Fernando de la Cuesta; Maria Gonzalez Barderas Journal: Dis Model Mech Date: 2018-06-19 Impact factor: 5.758