Literature DB >> 11818617

Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT.

U Joseph Schoepf1, Nicolaus Holzknecht, Thomas K Helmberger, Alexander Crispin, Cheng Hong, Christoph R Becker, Maximilian F Reiser.   

Abstract

PURPOSE: To compare different reconstruction thicknesses of thin-collimation multi-detector row spiral computed tomographic (CT) data sets of the chest for the detection of subsegmental pulmonary emboli.
MATERIALS AND METHODS: A multi-detector row spiral CT protocol for the diagnosis of pulmonary embolism was used that consisted of scanning the entire chest with 1-mm collimation within one breath hold. In 17 patients with central pulmonary embolism, the raw data were used to perform reconstructions with 1-mm, 2-mm, and 3-mm section thicknesses. For each set of images, each subsegmental artery was independently graded by three radiologists as open, containing emboli, or indeterminate.
RESULTS: For the rate of detection of emboli in subsegmental pulmonary arteries, use of the 1-mm section width yielded an average increase of 40% when compared with the use of 3-mm-thick sections (P <.001) and of 14% when compared with the use of 2-mm-thick sections (P =.001). With the use of 1-mm sections versus 3-mm sections, the number of indeterminate cases decreased by 70% (P =.001). Interrater agreement was substantially better with the use of 1-mm and 2-mm sections than with the use of 3-mm sections.
CONCLUSION: For the diagnosis of subsegmental pulmonary emboli at multi-detector row CT, the use of 1-mm section widths results in substantially higher detection rates and greater agreement between different readers than the use of thicker sections.

Entities:  

Mesh:

Year:  2002        PMID: 11818617     DOI: 10.1148/radiol.2222001802

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  54 in total

1.  British Thoracic Society guidelines for the management of suspected acute pulmonary embolism.

Authors: 
Journal:  Thorax       Date:  2003-06       Impact factor: 9.139

2.  Radiation dose in helical CT for detection of pulmonary embolism.

Authors:  S Diederich
Journal:  Eur Radiol       Date:  2003-07       Impact factor: 5.315

3.  Pulmonary embolism: is multislice CT the method of choice? For.

Authors:  Ieneke J C Hartmann; Mathias Prokop
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-01       Impact factor: 9.236

Review 4.  Contrast-enhanced MDCT of the thorax.

Authors:  A F Kopp; A Küttner; T Trabold; M Heuschmid; S Schröder; C D Claussen
Journal:  Eur Radiol       Date:  2003-11       Impact factor: 5.315

Review 5.  Cardiac and vascular MDCT: thoracic imaging.

Authors:  Andreas F Kopp; Axel Küttner; Tobias Trabold; Martin Heuschmid; Stephen Schröder; C D Claussen
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 6.  Multislice computed tomography angiography in the diagnosis of cardiovascular disease: 3D visualizations.

Authors:  Zhonghua Sun
Journal:  Front Med       Date:  2011-10-02       Impact factor: 4.592

7.  CTPA as the gold standard for the diagnosis of pulmonary embolism.

Authors:  Rosa M Estrada-Y-Martin; Sandra A Oldham
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-08-06       Impact factor: 2.924

8.  Optimisation of contrast medium volume and injection-related factors in CT pulmonary angiography: 64-slice CT study.

Authors:  Selma Uysal Ramadan; Pinar Kosar; Iclal Sonmez; Sevilay Karahan; Ugur Kosar
Journal:  Eur Radiol       Date:  2010-05-01       Impact factor: 5.315

9.  Prospective respiratory-triggered 64-slice CT pulmonary angiography for detection of pulmonary embolism--a feasibility study in a porcine model.

Authors:  Frank Oliver G Henes; Michael Groth; Marc Regier; Thorsten Bley; Hans-Dieter Nagel; Gerhard Adam; Philipp G C Begemann
Journal:  Emerg Radiol       Date:  2010-07-04

Review 10.  Is the lung scan alive and well? Facts and controversies in defining the role of lung scintigraphy for the diagnosis of pulmonary embolism in the era of MDCT.

Authors:  John H Reid; Emmanuel E Coche; Tomio Inoue; Edmund E Kim; Maurizio Dondi; Naoyuki Watanabe; Giuliano Mariani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-01-27       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.