Mechanisms isolated by frequency-doubling technology perimetry.

Andrew John Anderson1, Chris A Johnson.   

Abstract

PURPOSE: The frequency-doubling (FD) phenomenon describes the increase in apparent spatial frequency occurring when low-spatial-frequency sine wave gratings undergo rapid counterphase flicker. It is unclear whether the visual mechanisms isolated when pattern appearance is used as a threshold criterion are the same as when a simple detection criterion (as in FD perimetry) is used. It is also unclear whether the FD stimulus isolates mechanisms that differ from those isolated by spatially uniform flicker. In the current study, adaptation and spatiotemporal tuning functions were determined, using the FD stimulus, uniform flicker, and static (nonflickering) grating targets, to establish whether distinct mechanisms are isolated by the FD stimulus.
METHODS: Spatiotemporal tuning functions were determined in six observers, using an FD stimulus under conditions of detection and resolution and using spatially uniform flickering stimuli and static grating stimuli. The effect of light adaptation on these stimulus classes was also assessed. All stimuli were 10 degrees-wide squares.
RESULTS: Spatiotemporal tuning functions and adaptation characteristics were identical for both the FD detection and resolution paradigms. Spatially uniform flicker gave indistinguishable tuning functions and adaptation characteristics to the FD stimulus at 25 Hz and higher, but differed below this frequency. Static grating stimuli differed from FD stimuli in both tuning functions and adaptation characteristics.
CONCLUSIONS: Absolute detection of the FD stimulus involves mechanisms that are indistinguishable from those involved when a criterion based on spatial form (i.e., resolution of a pattern) is used, indicating that a simple detection criterion can be used in FD perimetry. The FD stimulus isolates similar mechanisms to spatially uniform flickering stimuli at high temporal frequencies.

Mesh:

Year:  2002        PMID: 11818383

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  15 in total

1.  African Descent and Glaucoma Evaluation Study (ADAGES): III. Ancestry differences in visual function in healthy eyes.

Authors:  Lyne Racette; Jeffrey M Liebmann; Christopher A Girkin; Linda M Zangwill; Sonia Jain; Lida M Becerra; Felipe A Medeiros; Christopher Bowd; Robert N Weinreb; Catherine Boden; Pamela A Sample
Journal:  Arch Ophthalmol       Date:  2010-05

2.  Short wavelength automated perimetry and tamoxifen use.

Authors:  A Eisner; D F Austin; J R Samples
Journal:  Br J Ophthalmol       Date:  2004-01       Impact factor: 4.638

3.  Frequency-doubling technology and retinal measurements with spectral-domain optical coherence tomography in preperimetric glaucoma.

Authors:  Takafumi Hirashima; Masanori Hangai; Masayuki Nukada; Noriko Nakano; Satoshi Morooka; Tadamichi Akagi; Atsushi Nonaka; Nagahisa Yoshimura
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-06-12       Impact factor: 3.117

4.  Topography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.

Authors:  J Landers; A Sharma; I Goldberg; S Graham
Journal:  Br J Ophthalmol       Date:  2006-01       Impact factor: 4.638

5.  Change blindness, aging, and cognition.

Authors:  Matthew Rizzo; Jondavid Sparks; Sean McEvoy; Sarah Viamonte; Ida Kellison; Shaun P Vecera
Journal:  J Clin Exp Neuropsychol       Date:  2008-12-03       Impact factor: 2.475

6.  Interpretation of the Humphrey Matrix 24-2 test in the diagnosis of preperimetric glaucoma.

Authors:  Jin A Choi; Na Young Lee; Chan Kee Park
Journal:  Jpn J Ophthalmol       Date:  2009-01-30       Impact factor: 2.447

7.  Sleep remains disturbed in patients with obstructive sleep apnea treated with positive airway pressure: a three-month cohort study using continuous actigraphy.

Authors:  Jon Tippin; Nazan Aksan; Jeffrey Dawson; Steven W Anderson; Matthew Rizzo
Journal:  Sleep Med       Date:  2016-08-16       Impact factor: 3.492

8.  Visual vigilance in drivers with obstructive sleep apnea.

Authors:  Jon Tippin; JonDavid Sparks; Matthew Rizzo
Journal:  J Psychosom Res       Date:  2009-05-19       Impact factor: 3.006

9.  Visual function-specific perimetry to identify glaucomatous visual loss using three different definitions of visual field abnormality.

Authors:  Ali Tafreshi; Pamela A Sample; Jeffrey M Liebmann; Christopher A Girkin; Linda M Zangwill; Robert N Weinreb; Maziar Lalezary; Lyne Racette
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-10-31       Impact factor: 4.799

10.  The association of office intraocular pressure fluctuation in ocular hypertension with frequency doubling technology perimetry abnormality.

Authors:  Volkan Dayanir; Sayime Aydin; Pinar Okyay
Journal:  Int Ophthalmol       Date:  2007-10-16       Impact factor: 2.031

View more