Literature DB >> 11818373

Development of efficient threshold strategies for frequency doubling technology perimetry using computer simulation.

Andrew Turpin1, Allison M McKendrick, Chris A Johnson, Algis J Vingrys.   

Abstract

PURPOSE: To develop new test procedures for frequency-doubling technology (FDT) perimetry that improve performance beyond those currently used.
METHODS: Two novel threshold estimation procedures were evaluated: a rapid, efficient binary search technique (REBS) and a maximum-likelihood estimation (ZEST) procedure. A computerized visual field simulation model was developed to determine the accuracy and efficiency of these procedures. This model was constructed using previously derived characteristics of FDT perimetry from both normal observers (n = 506) and those with glaucomatous visual field loss (n = 352). The computer simulation program was used to determine the best parameters for the two new procedures and the effect of variability and response errors on algorithm performance. Comparisons were made to the performance of the modified binary search (MOBS) procedure used in the current commercial implementation of the FDT perimeter.
RESULTS: Both the optimized REBS and ZEST procedures approximately halved the time required for FDT threshold testing without loss of accuracy or reproducibility.
CONCLUSIONS: With suitable parameter choices, comparable performance was achieved using either ZEST or REBS. Simulation results indicate that accurate thresholds can be measured with an optimized ZEST or REBS procedure in approximately half the time required by traditional estimation methods.

Entities:  

Mesh:

Year:  2002        PMID: 11818373

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  24 in total

1.  Measurement error of visual field tests in glaucoma.

Authors:  P G D Spry; C A Johnson; A M McKendrick; A Turpin
Journal:  Br J Ophthalmol       Date:  2003-01       Impact factor: 4.638

2.  The influence of varying the number of characters per row on the accuracy and reproducibility of the ETDRS visual acuity chart.

Authors:  Reuben R Shamir; Yael G Friedman; Leo Joskowicz; Michael Mimouni; Eytan Z Blumenthal
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-01-07       Impact factor: 3.117

3.  Characteristics of the normative database for the Humphrey matrix perimeter.

Authors:  Andrew John Anderson; Chris A Johnson; Murray Fingeret; John L Keltner; Paul G D Spry; Michael Wall; John S Werner
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-04       Impact factor: 4.799

4.  Effect of a variability-adjusted algorithm on the efficiency of perimetric testing.

Authors:  Stuart K Gardiner
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-05-06       Impact factor: 4.799

5.  Recognizing patterns of visual field loss using unsupervised machine learning.

Authors:  Siamak Yousefi; Michael H Goldbaum; Linda M Zangwill; Felipe A Medeiros; Christopher Bowd
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-21

6.  Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix 24-2 threshold strategy.

Authors:  P G D Spry; H M Hussin; J M Sparrow
Journal:  Br J Ophthalmol       Date:  2005-08       Impact factor: 4.638

7.  Comparison of visual field defects using matrix perimetry and standard achromatic perimetry.

Authors:  Avni Patel; Gadi Wollstein; Hiroshi Ishikawa; Joel S Schuman
Journal:  Ophthalmology       Date:  2006-11-21       Impact factor: 12.079

8.  Comparison of Snellen and Early Treatment Diabetic Retinopathy Study charts using a computer simulation.

Authors:  Reuben R Shamir; Yael Friedman; Leo Joskowicz; Michael Mimouni; Eytan Z Blumenthal
Journal:  Int J Ophthalmol       Date:  2016-01-18       Impact factor: 1.779

Review 9.  Diagnostic tools for glaucoma detection and management.

Authors:  Pooja Sharma; Pamela A Sample; Linda M Zangwill; Joel S Schuman
Journal:  Surv Ophthalmol       Date:  2008-11       Impact factor: 6.048

10.  Robot Assistants for Perimetry: A Study of Patient Experience and Performance.

Authors:  Allison M McKendrick; Astrid Zeman; Ping Liu; Dilek Aktepe; Illham Aden; Daisy Bhagat; Kieren Do; Huy D Nguyen; Andrew Turpin
Journal:  Transl Vis Sci Technol       Date:  2019-06-28       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.