Assessment of pacemaker chronotropic response: implementation of the Wilkoff mathematical model.

R A Freedman1, D L Hopper, J Mah, J Hummel, B L Wilkoff.   

Abstract

There are few practical guidelines for proper adjustment of rate responsive pacemaker sensor parameters. This study describes the application of the chronotropic assessment exercise protocol (CAEP) and the Wilkoff model of chronotropic response to assess the adjustment of pacemaker sensor parameters. In 31 patients implanted 1 month previously with a dual sensor pacemaker, pacemaker sensor parameters were adjusted to yield a peak sensor rate of 100 beats/min on a simple 6-minute walk (low intensity treadmill exercise [LITE] protocol); the maximum sensor rate was set to the age predicted maximum heart rate (220-age). The rate response behavior of the pacemaker was then assessed using the slope of metabolic-chronotropic relation (MCR) during CAEP exercise. After adjustments based on the LITE protocol, CAEP exercise yielded MCR slopes of 0.92 +/- 0.25 for the entire study group, which compares well with the predicted normal slope of 1. However, 7 of the 31 patients had sensor MCR slopes during CAEP exercise that were 2 SD or more below expected. To test the sensitivity of this approach to suboptimal pacemaker programming or suboptimal exercise, simulations were performed with the maximum sensor rate programmed below age-predicted maximum heart rate or with exercise truncated before maximum exertion; with these conditions, MCR slopes were sharply lower for the entire group. The authors conclude that a simple treadmill walk (LITE) allowed for optimum programming of sensor parameters in most patients, but in a minority the chronotropic behavior was underresponsive. Failure to appropriately adjust pacemaker maximum sensor rate or failure to achieve peak exercise sharply limits the accuracy of this methodology.

Entities:  

Mesh:

Year:  2001        PMID: 11817808     DOI: 10.1046/j.1460-9592.2001.01748.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  8 in total

Review 1.  Prevalence and management of chronotropic incompetence in heart failure.

Authors:  Peter H Brubaker; Dalane W Kitzman
Journal:  Curr Cardiol Rep       Date:  2007-05       Impact factor: 2.931

2.  Validating optimal function of the closed loop stimulation sensor with high right septal ventricular electrode placement in 'ablate and pace' patients.

Authors:  John Silberbauer; Paul S G Hong; Rick A Veasey; Nadeem A Maddekar; Wasing Taggu; Nikhil R Patel; Guy W Lloyd; Neil Sulke
Journal:  J Interv Card Electrophysiol       Date:  2009-07-23       Impact factor: 1.900

Review 3.  Paediatric models in motion: requirements for model-based decision support at the bedside.

Authors:  Jeffrey S Barrett
Journal:  Br J Clin Pharmacol       Date:  2015-01       Impact factor: 4.335

4.  Design and rationale of the assessment of proper physiologic response with rate adaptive pacing driven by minute ventilation or accelerometer (APPROPRIATE) trial.

Authors:  F Roosevelt Gilliam; Michael Giudici; Andrew Benn; Bruce Koplan; Kellie Jean Chase Berg; Stacia Merkel Kraus; Kira Q Stolen; Guy E Alvarez; Donald L Hopper; Bruce L Wilkoff
Journal:  J Cardiovasc Transl Res       Date:  2010-11-20       Impact factor: 4.132

5.  The restoration of chronotropic competence in heart failure patients with normal ejection fraction (RESET) study: rationale and design.

Authors:  David A Kass; Dalane W Kitzman; Guy E Alvarez
Journal:  J Card Fail       Date:  2009-10-07       Impact factor: 5.712

6.  Association of Chronic Kidney Disease With Chronotropic Incompetence in Heart Failure With Preserved Ejection Fraction.

Authors:  David A Klein; Daniel H Katz; Lauren Beussink-Nelson; Cynthia L Sanchez; Theresa A Strzelczyk; Sanjiv J Shah
Journal:  Am J Cardiol       Date:  2015-07-21       Impact factor: 2.778

Review 7.  Chronotropic incompetence: causes, consequences, and management.

Authors:  Peter H Brubaker; Dalane W Kitzman
Journal:  Circulation       Date:  2011-03-08       Impact factor: 39.918

8.  Impact of a right ventricular impedance sensor on the cardiovascular responses to exercise in pacemaker dependent patients.

Authors:  Linnea Cook; Corey Tomczak; Edward Busse; John Tsang; Wladyslaw Wojcik; Robert Haennel
Journal:  Indian Pacing Electrophysiol J       Date:  2005-07-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.