Literature DB >> 11817582

Field test of the reproducibility of the semiflexed metatarsophalangeal view in repeated radiographic examinations of subjects with osteoarthritis of the knee.

Steven A Mazzuca1, Kenneth D Brandt, Kenneth A Buckwalter, Kathleen A Lane, Barry P Katz.   

Abstract

OBJECTIVE: To estimate the reproducibility of the semiflexed metatarsophalangeal (MTP) view in repeat radiographic examinations of the knee of subjects with osteoarthritis (OA) with respect to radioanatomic alignment of the medial tibial plateau and the central x-ray beam and the precision of measurements of minimum medial tibiofemoral joint space width (JSW).
METHODS: Thirty-eight subjects with definite knee OA underwent 2 semiflexed MTP examinations on the same day. Radioanatomic alignment of the medial tibial plateau and the x-ray beam (distance between anterior and posterior margins of the plateau) was measured manually (Lequesne method). Manual measurements of the JSW in repeat radiographs also were obtained. The reproducibility of JSW measurements was estimated by the method of Bland and Altman.
RESULTS: Only 29% of the initial semiflexed MTP radiographs exhibited satisfactory radioanatomic alignment (intermargin distance < or =1 mm). However, intermargin distances in initial and repeat radiographs were highly correlated (r = 0.86, P < 0.01). In 89% of knees, the intermargin distance in the first examination was reproduced (+/- 1 mm) in the second examination. The standard error of measurement (mean of within-knee standard deviations of repeat JSW values) was 0.30 mm. The magnitude of discrepancy between repeat measurements of JSW was related positively to overall radiographic severity of knee OA (P < 0.05).
CONCLUSION: The semiflexed MTP protocol affords highly reproducible radioanatomic positioning of the knee, although misalignment of the medial tibial plateau and the x-ray beam occurs in >70% of cases. Precision of measurement of JSW in the semiflexed MTP view approaches that associated with fluoroscopically assisted positioning protocols. However, the consequences of poor, albeit reproducible, alignment of the knee in serial semiflexed MTP radiographs in longitudinal studies of OA progression are currently unknown.

Entities:  

Mesh:

Year:  2002        PMID: 11817582     DOI: 10.1002/1529-0131(200201)46:1<109::aid-art10040>3.0.co;2-o

Source DB:  PubMed          Journal:  Arthritis Rheum        ISSN: 0004-3591


  13 in total

1.  Fixed-flexion radiography of the knee provides reproducible joint space width measurements in osteoarthritis.

Authors:  Manish Kothari; Ali Guermazi; Gabriele von Ingersleben; Yves Miaux; Martine Sieffert; Jon E Block; Randall Stevens; Charles G Peterfy
Journal:  Eur Radiol       Date:  2004-05-19       Impact factor: 5.315

Review 2.  State-of-the-art disease-modifying osteoarthritis drugs.

Authors:  Roland W Moskowitz; Michele Hooper
Journal:  Curr Rheumatol Rep       Date:  2005-03       Impact factor: 4.592

3.  Semi-automated digital image analysis of joint space width in knee radiographs.

Authors:  J E Schmidt; K K Amrami; A Manduca; K R Kaufman
Journal:  Skeletal Radiol       Date:  2005-05-25       Impact factor: 2.199

4.  Comparison of quantitative and semiquantitative indicators of joint space narrowing in subjects with knee osteoarthritis.

Authors:  S A Mazzuca; K D Brandt; B P Katz; K A Lane; K A Buckwalter
Journal:  Ann Rheum Dis       Date:  2005-05-26       Impact factor: 19.103

Review 5.  Imaging osteoarthritis: magnetic resonance imaging versus x-ray.

Authors:  Charles Peterfy; Manish Kothari
Journal:  Curr Rheumatol Rep       Date:  2006-02       Impact factor: 4.592

6.  Digital radiographic assessment of tibiofemoral joint space width: a variance component analysis.

Authors:  Heidi L Oksendahl; Nigel Gomez; Colleen S Thomas; Gary D Badger; Michael J Hulstyn; Paul D Fadale; Braden C Fleming
Journal:  J Knee Surg       Date:  2009-07       Impact factor: 2.757

7.  Reproducibility of joint space width and the intermargin distance measurements in patients with medial osteoarthritis of the knee in various degrees of flexion.

Authors:  Toshiaki Takahashi; Norio Yamanaka; Masahiko Ikeuchi; Haruyasu Yamamoto
Journal:  Skeletal Radiol       Date:  2008-09-05       Impact factor: 2.199

Review 8.  The evolution of articular cartilage imaging and its impact on clinical practice.

Authors:  Carl S Winalski; Prabhakar Rajiah
Journal:  Skeletal Radiol       Date:  2011-08-17       Impact factor: 2.199

9.  The effect of glucosamine and/or chondroitin sulfate on the progression of knee osteoarthritis: a report from the glucosamine/chondroitin arthritis intervention trial.

Authors:  Allen D Sawitzke; Helen Shi; Martha F Finco; Dorothy D Dunlop; Clifton O Bingham; Crystal L Harris; Nora G Singer; John D Bradley; David Silver; Christopher G Jackson; Nancy E Lane; Chester V Oddis; Fred Wolfe; Jeffrey Lisse; Daniel E Furst; Domenic J Reda; Roland W Moskowitz; H James Williams; Daniel O Clegg
Journal:  Arthritis Rheum       Date:  2008-10

10.  Minimum joint space width (mJSW) of patellofemoral joint on standing "skyline" radiographs: test-retest reproducibility and comparison with quantitative magnetic resonance imaging (qMRI).

Authors:  Paolo Simoni; Sanaa Jamali; Adelin Albert; Saara Totterman; Edward Schreyer; Jose G Tamez-Peña; Bruno Beomonte Zobel; Victoria Alvarez Miezentseva; Philippe Gillet
Journal:  Skeletal Radiol       Date:  2013-08-24       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.