Literature DB >> 11817062

Dual-chamber pacemaker implantation via the cephalic vein in healthy equids.

G van Loon1, W Fonteyne, H Rottiers, R Tavernier, L Jordaens, L D'Hont, R Colpaert, T De Clercq, P Deprez.   

Abstract

The purpose of the present study was to develop a feasible and safe technique for dual-chamber pacemaker implantation in healthy horses. Implantation was performed in a standing, tranquilized horse and in ponies. Atrial and ventricular leads were transvenously inserted through the cephalic vein, and a subcutaneous pacemaker pocket was created between the lateral pectoral groove and the manubrium sterni in 6 equids. Positioning of each lead was guided by echocardiography and by measuring the electrical characteristics of the lead. The implantation procedure lasted about 4 hours in each animal and was well tolerated. In all animals, dual-chamber pacemaker function was obtained, and these results remained good throughout the follow-up period. At the time of implantation, atrial and ventricular sensing were between 2.1 and 7.2 mV and 7.8 and 16.8 mV, respectively, and atrial and ventricular pacing thresholds at 0.5 millisecond varied from 0.5 to 0.7 V and from 0.3 to 1.0 V, respectively. Six months after the implantation, sensing values varied from 2 to 10 mV for the atrial lead and from 2 to 16 mV for the ventricular lead, while pacing thresholds at 0.5 millisecond varied from less than 0.5 to 2.5 V for the right atrium and from less than 0.5 to 5.0 V for the right ventricle. Atrial lead dislodgment occurred in 2 animals, requiring insertion of a new lead. Ventricular lead dislodgment was not observed.

Entities:  

Mesh:

Year:  2001        PMID: 11817062     DOI: 10.1892/0891-6640(2001)015<0564:dpivtc>2.3.co;2

Source DB:  PubMed          Journal:  J Vet Intern Med        ISSN: 0891-6640            Impact factor:   3.333


  7 in total

1.  Third-Degree Atrioventricular Block and Collapse Associated with Eosinophilic Myocarditis in a Horse.

Authors:  D Luethy; J Slack; M S Kraus; A R Gelzer; P Habecker; A L Johnson
Journal:  J Vet Intern Med       Date:  2017-03-14       Impact factor: 3.333

2.  Time-dependent antiarrhythmic effects of flecainide on induced atrial fibrillation in horses.

Authors:  Helena Carstensen; Eva Z Hesselkilde; Merle Fenner; Ameli V Loft-Andersen; Mette Flethøj; Jørgen K Kanters; Stefan M Sattler; Jacob Tfelt-Hansen; Steen Pehrson; Thomas Jespersen; Rikke Buhl
Journal:  J Vet Intern Med       Date:  2018-08-22       Impact factor: 3.333

3.  Longitudinal study of electrical, functional and structural remodelling in an equine model of atrial fibrillation.

Authors:  Eva Zander Hesselkilde; Helena Carstensen; Mette Flethøj; Merle Fenner; Ditte Dybvald Kruse; Stefan M Sattler; Jacob Tfelt-Hansen; Steen Pehrson; Thomas Hartig Braunstein; Jonas Carlson; Pyotr G Platonov; Thomas Jespersen; Rikke Buhl
Journal:  BMC Cardiovasc Disord       Date:  2019-10-21       Impact factor: 2.298

4.  Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope.

Authors:  Lisa De Lange; Glenn Van Steenkiste; Ingrid Vernemmen; Lisse Vera; Kristel M C Cromheeke; Ulla Walser; Hans Meert; Annelies Decloedt; Gunther van Loon
Journal:  J Vet Intern Med       Date:  2021-11-06       Impact factor: 3.333

5.  Measurement variability of right atrial and ventricular monophasic action potential and refractory period measurements in the standing non-sedated horse.

Authors:  Dominique De Clercq; Barbara Broux; Lisse Vera; Annelies Decloedt; Gunther van Loon
Journal:  BMC Vet Res       Date:  2018-03-20       Impact factor: 2.741

6.  Effect of induced chronic atrial fibrillation on exercise performance in Standardbred trotters.

Authors:  Rikke Buhl; Helena Carstensen; Eva Zander Hesselkilde; Bjørg Zinkernagel Klein; Karen Margrethe Hougaard; Kirsten Bomberg Ravn; Ameli Victoria Loft-Andersen; Merle Friederike Fenner; Christian Pipper; Thomas Jespersen
Journal:  J Vet Intern Med       Date:  2018-05-10       Impact factor: 3.333

7.  Single-Chamber Cardiac Pacemaker Implantation in a Donkey with Complete AV Block: A Long-Term Follow-Up.

Authors:  Markéta Sedlinská; Radovan Kabeš; Miroslav Novák; Filip Kološ; Pavlína Melková
Journal:  Animals (Basel)       Date:  2021-03-09       Impact factor: 2.752

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.