Literature DB >> 11816621

Quantitative magnetic resonance first-pass perfusion analysis: inter- and intraobserver agreement.

O M Mühling1, M E Dickson, A Zenovich, Y Huang, B V Wilson, R F Wilson, I S Anand, R T Seethamraju, M Jerosch-Herold, N M Wilke.   

Abstract

Magnetic resonance first-pass (MRFP) imaging awaits longitudinal clinical trials for quantification of myocardial perfusion. The purpose of this study was to assess inter- and intraobserver agreement of this method. Seventeen MRFP studies (14 rest and 3 under adenosine-induced hyperemia) from 14 patients were acquired. Two observers visually graded study quality. Each study was subdivided into eight regions. Both observers analyzed all 17 studies (8 x 17 = 136 regions) for interobserver agreement. Each observer then analyzed 10 of the 17 studies a second time (2 x 8 x 10 = 160 regions) for intraobserver agreement. Signal intensity curves were obtained with Argus software (Siemens, Iselin, NJ). The maximum amplitude of the impulse response function (Rmax) and the change of signal intensity (deltaSImax) of the contrast bolus were determined. Intraclass correlation coefficient was used to determine intra- and interobserver agreement. The quality was good or excellent in 14 studies. Intraobserver agreement of Rmax and deltaSImax were good (0.85 and 0.80, n = 160). Interobserver agreement of Rmax was fair (0.55, n = 136) but improved after exclusion of poor-quality studies (0.88, n = 112). Interobserver agreement of deltaSImax was good (0.73) and improved less than Rmax with study quality (0.83). Interobserver agreement for Rmax in individual myocardial regions before and after exclusion of studies with poor quality changed most markedly in lateral and posterior regions (0.69 and 0.65 vs. 0.97 and 0.94), where signal-to-noise ratios were reduced compared with anteroseptal regions (p < 0.01). Analysis of MRFP images provides good intraobserver agreement. Interobserver agreement of the quantitative perfusion analysis is good under the premise of good image quality.

Entities:  

Mesh:

Year:  2001        PMID: 11816621     DOI: 10.1081/jcmr-100107473

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


  12 in total

1.  Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging.

Authors:  Peter Hunold; Stefan Maderwald; Holger Eggebrecht; Florian M Vogt; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2003-11-26       Impact factor: 5.315

2.  High-resolution myocardial perfusion imaging at 3 T: comparison to 1.5 T in healthy volunteers.

Authors:  K Strach; C Meyer; D Thomas; C P Naehle; C Schmitz; H Litt; A Bernstein; B Cheng; H Schild; T Sommer
Journal:  Eur Radiol       Date:  2007-02-16       Impact factor: 5.315

3.  Variability in quantitative cardiac magnetic resonance perfusion analysis.

Authors:  K Bratis; Eike Nagel
Journal:  J Thorac Dis       Date:  2013-06       Impact factor: 2.895

4.  Going with the flow: how reproducible are cardiac magnetic resonance measurements of myocardial perfusion?

Authors:  John Biglands; Sven Plein
Journal:  J Thorac Dis       Date:  2013-06       Impact factor: 2.895

5.  Regional functional recovery after acute myocardial infarction: a cardiac magnetic resonance long-term study.

Authors:  Agnes Mayr; Kathrin Pedarnig; Gert Klug; Michael Schocke; Otmar Pachinger; Werner Jaschke; Bernhard Metzler
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-01       Impact factor: 2.357

6.  Perfusion cardiovascular magnetic resonance: Comparison of an advanced, high-resolution and a standard sequence.

Authors:  Geraint Morton; Masaki Ishida; Andreas Schuster; Shazia Hussain; Tobias Schaeffter; Amedeo Chiribiri; Eike Nagel
Journal:  J Cardiovasc Magn Reson       Date:  2012-06-09       Impact factor: 5.364

7.  Interstudy repeatability of self-gated quantitative myocardial perfusion MRI.

Authors:  Devavrat Likhite; Promporn Suksaranjit; Ganesh Adluru; Nan Hu; Cindy Weng; Eugene Kholmovski; Chris McGann; Brent Wilson; Edward DiBella
Journal:  J Magn Reson Imaging       Date:  2015-12-13       Impact factor: 4.813

8.  The delay of contrast arrival in magnetic resonance first-pass perfusion imaging: a novel non-invasive parameter detecting collateral-dependent myocardium.

Authors:  O M Muehling; A Huber; C Cyran; S O Schoenberg; M Reiser; G Steinbeck; M Nabauer; M Jerosch-Herold
Journal:  Heart       Date:  2007-03-07       Impact factor: 5.994

9.  Reproducibility of adenosine stress cardiovascular magnetic resonance in multi-vessel symptomatic coronary artery disease.

Authors:  Sharon Chih; Peter S Macdonald; Michael P Feneley; Matthew Law; Robert M Graham; Jane A McCrohon
Journal:  J Cardiovasc Magn Reson       Date:  2010-07-21       Impact factor: 5.364

10.  Inter-observer agreement and diagnostic accuracy of myocardial perfusion reserve quantification by cardiovascular magnetic resonance at 3 Tesla in comparison to quantitative coronary angiography.

Authors:  Katharina Ikuye; Dominik Buckert; Lisa Schaaf; Thomas Walcher; Wolfgang Rottbauer; Peter Bernhardt
Journal:  J Cardiovasc Magn Reson       Date:  2013-03-27       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.