Literature DB >> 11816591

Effect of lipophilic ion-exchanger leaching on the detection limit of carrier-based ion-selective electrodes.

M Telting-Diaz1, E Bakker.   

Abstract

The equilibrium partitioning of lipophilic ion-exchanger salts from ion-selective polymeric membrane electrodes (ISEs) and its possible effect on the lower detection limit of these sensors is described. Predictions are made on the basis of various parameters, including the knowledge of tetraphenylborate potassium salt partitioning constants, the selectivity of ionophore-free ion-exchanger membranes, and ionophore stability constants in the membrane. Ion-exchanger lipophilicities are significantly increased if the membrane contains an ionophore that strongly binds the primary ion. Predicted detection limits are on the order of 10(-5)-10(-8) M for ionophore-free membranes, and may reach levels as low as 10(-18) M with adequate ionophores in the membrane. Experiments are performed for well-described lead-selective membranes containing different tetraphenylborate derivatives, and detection limits appear to be independent of the ion-exchanger used. However, they are much higher if a more hydrophilic carborane cation-exchanger is incorporated in the membrane. The first finding confirms recent theory, which states that transmembrane ion fluxes, given by a small level of ion-exchange at the sample side by interfering ions, normally dictate the detection limit of these sensing systems. Predicted detection limits on the basis of ion-exchanger leaching alone are here listed for a number of analytically relevant cases. For potassium-selective electrodes containing BME-44 and tetraphenylborate as ion-exchanger, the experimental detection limits are in agreement with predicted values. These results suggest that the detection limit of many current ISEs for ultratrace level analysis are, in optimal cases, dictated by transmembrane ion fluxes; however, because improved chemical solutions are being developed to reduce such effects, simple ion-exchanger partitioning may indeed become an important mechanism that can give higher detection limits than practically desired, and should not be ruled out.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11816591     DOI: 10.1021/ac010526h

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion-Selective Electrodes.

Authors:  Zsófia Szigeti; Tamás Vigassy; Eric Bakker; Ernö Pretsch
Journal:  Electroanalysis       Date:  2006-07-01       Impact factor: 3.223

Review 2.  Modern potentiometry.

Authors:  Eric Bakker; Ernö Pretsch
Journal:  Angew Chem Int Ed Engl       Date:  2007       Impact factor: 15.336

3.  Materials and Interface Designs of Waterproof Field-Effect Transistor Arrays for Detection of Neurological Biomarkers.

Authors:  Yan Dong; Shulin Chen; Tzu-Li Liu; Jinghua Li
Journal:  Small       Date:  2022-01-13       Impact factor: 13.281

4.  Ion-Selective Carbon Nanotube Field-Effect Transistors for Monitoring Drug Effects on Nicotinic Acetylcholine Receptor Activation in Live Cells.

Authors:  Youngtak Cho; Viet Anh Pham Ba; Jin-Young Jeong; Yoonji Choi; Seunghun Hong
Journal:  Sensors (Basel)       Date:  2020-06-30       Impact factor: 3.576

5.  Selective ion sensing with high resolution large area graphene field effect transistor arrays.

Authors:  Ibrahim Fakih; Oliver Durnan; Farzaneh Mahvash; Ilargi Napal; Alba Centeno; Amaia Zurutuza; Viviane Yargeau; Thomas Szkopek
Journal:  Nat Commun       Date:  2020-06-26       Impact factor: 14.919

Review 6.  Modern Electrode Technologies for Ion and Molecule Sensing.

Authors:  William S Skinner; Keat Ghee Ong
Journal:  Sensors (Basel)       Date:  2020-08-14       Impact factor: 3.576

Review 7.  Forward-Looking Roadmaps for Long-Term Continuous Water Quality Monitoring: Bottlenecks, Innovations, and Prospects in a Critical Review.

Authors:  Yuankai Huang; Xingyu Wang; Wenjun Xiang; Tianbao Wang; Clifford Otis; Logan Sarge; Yu Lei; Baikun Li
Journal:  Environ Sci Technol       Date:  2022-04-20       Impact factor: 11.357

8.  Determination of the Total Phenolic Content in Wine Samples Using Potentiometric Method Based on Permanganate Ion as an Indicator.

Authors:  Ziqi Sun; Yufeng Zhang; Xinyue Xu; Minglin Wang; Lijuan Kou
Journal:  Molecules       Date:  2019-09-09       Impact factor: 4.411

  8 in total