Literature DB >> 11814719

Stability-indicating methods for the determination of doxazosin mezylate and celecoxib.

L I Bebawy1, A A Moustafa, N F Abo-Talib.   

Abstract

Two stability-indicating methods were developed for the determination of doxazosin mesylate (I) and celecoxib (II) in the presence of their degradation products. The first method depends on the use of first derivative spectrophotometry (D(1)) at 256, 269 nm for (I) and (II), respectively. This method determines (I) and (II) in concentration ranges of 0.8-12 and 1-20 microg ml(-1) with mean percentage accuracies of 99.21+/-0.88 and 99.59+/-1.67% for (I) and (II), respectively. The second method depends on the quantitative densitometric evaluation of thin-layer chromatography of (I) and (II) in the presence of their degradation products without any interference. Methylisobutyl ketone-glacial acetic acid-water (20:10:10) was used as a mobile phase for (I) and cyclohexane-dichloromethane-diethyleamine (50:40:10) for (II). The chromatograms were scanned at 248 and 253 nm for (I) and (II), respectively. This method determines (I) and (II) in concentration ranges of l-4 microg per spot for both drugs with mean percentage accuracies of 100.19+/-0.95 and 99.91+/-1.95% for (I) and (II), respectively. The suggested methods were used to determine doxazosin mesylate and celecoxib in bulk powder, laboratory-prepared mixtures and pharmaceutical dosage forms (cardura tablet and celebrex capsule). The results obtained by applying the proposed methods were statistically analysed and compared with those obtained by the reported methods.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11814719     DOI: 10.1016/s0731-7085(01)00523-4

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  4 in total

1.  Stability of celecoxib oral suspension.

Authors:  Ronald F Donnelly; Elena Pascuet; Carmen Ma; Régis Vaillancourt
Journal:  Can J Hosp Pharm       Date:  2009-11

2.  Rapid and sensitive online determination of some selective α1-blockers by flow injection analysis with micelle-enhanced fluorescence detection.

Authors:  Niveen A Mohamed; Sameh Ahmed; Sally A El Zohny
Journal:  J Fluoresc       Date:  2013-07-20       Impact factor: 2.217

3.  Determination of Alkyl Methanesulfonates in Doxazosin Mesylate by Gas Chromatography-mass Spectrometer.

Authors:  C Sitaram; R B Rupakula; B N Reddy; C S P Sastry
Journal:  Indian J Pharm Sci       Date:  2011-01       Impact factor: 0.975

4.  Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Prazosin, Terazosin, and Doxazosin in Pharmaceutical Formulations.

Authors:  Alankar Shrivastava; Vipin B Gupta
Journal:  Sci Pharm       Date:  2012-05-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.