Literature DB >> 11812714

The timing of intravenous crystalloid administration and incidence of cardiovascular side effects during spinal anesthesia: the results from a randomized controlled trial.

José L Mojica1, Héctor J Meléndez, Leonelo E Bautista.   

Abstract

UNLABELLED: We conducted a randomized clinical trial to evaluate the efficacy of crystalloids in preventing spinal-induced hypotension (SIH) and cardiovascular side effects (CVSE) in a group of surgical patients. Participants were assigned to receive lactated Ringer's solution at 1-2 mL/min (Placebo group, n = 142); lactated Ringer's at 20 mL/kg starting 20 min before spinal block (n = 130); or lactated Ringer's at 20 mL/kg starting at the time of spinal block (n = 132). SIH was defined as a decrease of > or = 30% in baseline systolic blood pressure, and CVSE as SIH plus nausea, vomiting, or faintness requiring treatment. The incidence of SIH was similar in all treatment groups. Compared to placebo, crystalloid administration at the time of spinal block resulted in a significant reduction in the proportion of patients developing CVSE from 9.9% to 2.3%. The corresponding relative proportion was 0.23 (95% confidence interval, 0.07-0.78; P = 0.019), and one additional case of CVSE was avoided for each 13 patients receiving crystalloids at the time of spinal block instead of placebo. Administration of crystalloids at the time of spinal block seems to be effective because it provides additional intravascular fluids during the period of highest risk of CVSE after spinal anesthesia. IMPLICATIONS: Crystalloids are frequently administered to nonobstetric patients minutes before spinal anesthesia to prevent cardiovascular side effects (CVSE). This randomized controlled trial shows that although crystalloids administered before spinal block result in no clinical benefit, they significantly reduce the risk of CVSE when administered at the time of spinal block.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11812714     DOI: 10.1097/00000539-200202000-00039

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  8 in total

Review 1.  [Recent standards in management of obstetric anesthesia].

Authors:  Maximiliaan van Erp; Clemens Ortner; Stefan Jochberger; Klaus Ulrich Klein
Journal:  Wien Med Wochenschr       Date:  2017-07-25

2.  A comparison of spinal anesthesia characteristics following intrathecal bupivacaine or levobupivacaine in lumbar disc surgery.

Authors:  Monica Del-Rio-Vellosillo; Jose Javier Garcia-Medina; Maria Dolores Pinazo-Duran; Antonio Abengochea-Cotaina; Antonio Abengochea-Cotania
Journal:  Eur Spine J       Date:  2014-01-24       Impact factor: 3.134

3.  Subarachnoid block for caesarean section in severe preeclampsia.

Authors:  Sujata Chaudhary; Rashmi Salhotra
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2011-04

4.  Prevention of altered hemodynamics after spinal anesthesia: A comparison of volume preloading with tetrastarch, succinylated gelatin and ringer lactate solution for the patients undergoing lower segment caesarean section.

Authors:  Tapobrata Mitra; Anjan Das; Saikat Majumdar; Tapas Bhattacharyya; Rahul Deb Mandal; Bimal Kumar Hajra
Journal:  Saudi J Anaesth       Date:  2014-10

Review 5.  Co-loading or pre-loading for prevention of hypotension after spinal anaesthesia! a therapeutic dilemma.

Authors:  Sukhminder Jit Singh Bajwa; Ashish Kulshrestha; Ravi Jindal
Journal:  Anesth Essays Res       Date:  2013 May-Aug

6.  Prevention of hypotension induced by combined spinal epidural anesthesia using continuous infusion of vasopressin: A randomized trial.

Authors:  Chetna Shamshery; Ashish Kannaujia; Rajashree Madabushi; Dinesh Singh; Divya Srivastava; Shobhana Jafa
Journal:  Anesth Essays Res       Date:  2016 Sep-Dec

7.  Comparative Dose-Response Study on the Infusion of Norepinephrine Combined with Crystalloid Coload versus Colloid Coload for Preventing Hypotension During Spinal Anesthesia for Cesarean Delivery.

Authors:  Wei-Dong Jin; Jun-Qin Mao; Jie Liu; Gang Liang; Chao Jiang; Zhi-Min Sheng
Journal:  Drug Des Devel Ther       Date:  2022-08-06       Impact factor: 4.319

8.  Correlation between Weight of the Baby and the Level of Sensory Blockade in Spinal Anaesthesia for Caesarean Section: An Observational Study.

Authors:  K S Sushma; Ashwini H Ramaswamy; Safiya I Shaikh
Journal:  Anesth Essays Res       Date:  2018 Apr-Jun
  8 in total