Literature DB >> 11811827

Computer-aided characterization of mammographic masses: accuracy of mass segmentation and its effects on characterization.

B Sahiner1, N Petrick, H P Chan, L M Hadjiiski, C Paramagul, M A Helvie, M N Gurcan.   

Abstract

Mass segmentation is used as the first step in many computer-aided diagnosis (CAD) systems for classification of breast masses as malignant or benign. The goal of this paper was to study the accuracy of an automated mass segmentation method developed in our laboratory, and to investigate the effect of the segmentation stage on the overall classification accuracy. The automated segmentation method was quantitatively compared with manual segmentation by two expert radiologists (R1 and R2) using three similarity or distance measures on a data set of 100 masses. The area overlap measures between R1 and R2, the computer and R1, and the computer and R2 were 0.76 +/- 0.13, 0.74 +/- 0.11, and 0.74 +/- 0.13, respectively. The interobserver difference in these measures between the two radiologists was compared with the corresponding differences between the computer and the radiologists. Using three similarity measures and data from two radiologists, a total of six statistical tests were performed. The difference between the computer and the radiologist segmentation was significantly larger than the interobserver variability in only one test. Two sets of texture, morphological, and spiculation features, one based on the computer segmentation, and the other based on radiologist segmentation, were extracted from a data set of 249 films from 102 patients. A classifier based on stepwise feature selection and linear discriminant analysis was trained and tested using the two feature sets. The leave-one-case-out method was used for data sampling. For case-based classification, the area Az under the receiver operating characteristic (ROC) curve was 0.89 and 0.88 for the feature sets based on the radiologist segmentation and computer segmentation, respectively. The difference between the two ROC curves was not statistically significant.

Entities:  

Mesh:

Year:  2001        PMID: 11811827     DOI: 10.1109/42.974922

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  26 in total

1.  Radial-searching contour extraction method based on a modified active contour model for mammographic masses.

Authors:  Toshiaki Nakagawa; Takeshi Hara; Hiroshi Fujita; Katsuhei Horita; Takuji Iwase; Tokiko Endo
Journal:  Radiol Phys Technol       Date:  2008-05-08

2.  Assessing heterogeneity of lesion enhancement kinetics in dynamic contrast-enhanced MRI for breast cancer diagnosis.

Authors:  A Karahaliou; K Vassiou; N S Arikidis; S Skiadopoulos; T Kanavou; L Costaridou
Journal:  Br J Radiol       Date:  2010-04       Impact factor: 3.039

3.  Computer-aided classification of breast masses: performance and interobserver variability of expert radiologists versus residents.

Authors:  Swatee Singh; Jeff Maxwell; Jay A Baker; Jennifer L Nicholas; Joseph Y Lo
Journal:  Radiology       Date:  2010-10-22       Impact factor: 11.105

4.  Computer-aided diagnosis of pulmonary nodules on CT scans: segmentation and classification using 3D active contours.

Authors:  Ted W Way; Lubomir M Hadjiiski; Berkman Sahiner; Heang-Ping Chan; Philip N Cascade; Ella A Kazerooni; Naama Bogot; Chuan Zhou
Journal:  Med Phys       Date:  2006-07       Impact factor: 4.071

5.  Characterization of mammographic masses based on level set segmentation with new image features and patient information.

Authors:  Jiazheng Shi; Berkman Sahiner; Heang-Ping Chan; Jun Ge; Lubomir Hadjiiski; Mark A Helvie; Alexis Nees; Yi-Ta Wu; Jun Wei; Chuan Zhou; Yiheng Zhang; Jing Cui
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

6.  Computer-aided detection systems for breast masses: comparison of performances on full-field digital mammograms and digitized screen-film mammograms.

Authors:  Jun Wei; Lubomir M Hadjiiski; Berkman Sahiner; Heang-Ping Chan; Jun Ge; Marilyn A Roubidoux; Mark A Helvie; Chuan Zhou; Yi-Ta Wu; Chintana Paramagul; Yiheng Zhang
Journal:  Acad Radiol       Date:  2007-06       Impact factor: 3.173

7.  Automated volume analysis of head and neck lesions on CT scans using 3D level set segmentation.

Authors:  Ethan Street; Lubomir Hadjiiski; Berkman Sahiner; Sachin Gujar; Mohannad Ibrahim; Suresh K Mukherji; Heang-Ping Chan
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

Review 8.  Anniversary paper: History and status of CAD and quantitative image analysis: the role of Medical Physics and AAPM.

Authors:  Maryellen L Giger; Heang-Ping Chan; John Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Urinary bladder segmentation in CT urography (CTU) using CLASS.

Authors:  Lubomir Hadjiiski; Heang-Ping Chan; Richard H Cohan; Elaine M Caoili; Yuen Law; Kenny Cha; Chuan Zhou; Jun Wei
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

10.  Level set segmentation of breast masses in contrast-enhanced dedicated breast CT and evaluation of stopping criteria.

Authors:  Hsien-Chi Kuo; Maryellen L Giger; Ingrid Reiser; John M Boone; Karen K Lindfors; Kai Yang; Alexandra Edwards
Journal:  J Digit Imaging       Date:  2014-04       Impact factor: 4.056

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.