Literature DB >> 11811500

Internal contamination of a 2-component implant system after occlusal loading and provisionally luted reconstruction with or without a washer device.

L Rimondini1, C Marin, F Brunella, M Fini.   

Abstract

BACKGROUND: Microbial internal contamination of oral implants has been suggested as being responsible for inflammatory infiltration of peri-implant tissues at the fixture-abutment interface of 2-stage and 2-component implant systems; it is also considered as a potential source of pathogens. The present in vivo study evaluated contamination of the inner abutment-implant retaining screw, after occlusal loading and provisionally-luted reconstruction with or without a washer device.
METHODS: Eight 2-component oral implants sealed with an o-ring silicon washer device and 9 without a seal were placed in 7 patients with high oral hygiene standards. Two months after prosthetic reconstruction, crowns and internal screws were removed, and organic and inorganic screw contamination was examined by scanning electron microscopy and energy dispersive x-ray spectroscopy (EDS) analysis.
RESULTS: An amorphous and crystalline contamination, suggestive of calcium and phosphate compounds, was seen on all screw surfaces. Microbial contamination was more frequently observed in the unsealed group. No differences in bacterial morphotypes were observed between the sealed and unsealed implants. Cocci were the most representative morphotypes, while rods were seldom seen.
CONCLUSIONS: In clinical situations, leakage occurs at the implant-abutment interface, although bacterial contamination is limited in patients with high oral hygiene standards. Contamination may be reduced by using a washer device.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11811500     DOI: 10.1902/jop.2001.72.12.1652

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  3 in total

1.  Micro-leakage at the implant-abutment interface with different tightening torques in vitro.

Authors:  João Paulo da Silva-Neto; Marcel Santana Prudente; Thiago de Almeida Prado Naves Carneiro; Mauro Antônio de Arruda Nóbilo; Mario Paulo Amante Penatti; Flávio Domingues das Neves
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

2.  Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessment.

Authors:  Jacques-Henri Torres; Michael Mechali; Olivier Romieu; Paul Tramini; Sylvie Callas; Frédéric Jg Cuisinier; Bernard Levallois
Journal:  Biomed Eng Online       Date:  2011-04-14       Impact factor: 2.819

3.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.