L Rimondini1, C Marin, F Brunella, M Fini. 1. Department of Oral Pathology and Medicine, University of Milan, Italy. pib1431@iperbole.bologna.it
Abstract
BACKGROUND: Microbial internal contamination of oral implants has been suggested as being responsible for inflammatory infiltration of peri-implant tissues at the fixture-abutment interface of 2-stage and 2-component implant systems; it is also considered as a potential source of pathogens. The present in vivo study evaluated contamination of the inner abutment-implant retaining screw, after occlusal loading and provisionally-luted reconstruction with or without a washer device. METHODS: Eight 2-component oral implants sealed with an o-ring silicon washer device and 9 without a seal were placed in 7 patients with high oral hygiene standards. Two months after prosthetic reconstruction, crowns and internal screws were removed, and organic and inorganic screw contamination was examined by scanning electron microscopy and energy dispersive x-ray spectroscopy (EDS) analysis. RESULTS: An amorphous and crystalline contamination, suggestive of calcium and phosphate compounds, was seen on all screw surfaces. Microbial contamination was more frequently observed in the unsealed group. No differences in bacterial morphotypes were observed between the sealed and unsealed implants. Cocci were the most representative morphotypes, while rods were seldom seen. CONCLUSIONS: In clinical situations, leakage occurs at the implant-abutment interface, although bacterial contamination is limited in patients with high oral hygiene standards. Contamination may be reduced by using a washer device.
BACKGROUND: Microbial internal contamination of oral implants has been suggested as being responsible for inflammatory infiltration of peri-implant tissues at the fixture-abutment interface of 2-stage and 2-component implant systems; it is also considered as a potential source of pathogens. The present in vivo study evaluated contamination of the inner abutment-implant retaining screw, after occlusal loading and provisionally-luted reconstruction with or without a washer device. METHODS: Eight 2-component oral implants sealed with an o-ring silicon washer device and 9 without a seal were placed in 7 patients with high oral hygiene standards. Two months after prosthetic reconstruction, crowns and internal screws were removed, and organic and inorganic screw contamination was examined by scanning electron microscopy and energy dispersive x-ray spectroscopy (EDS) analysis. RESULTS: An amorphous and crystalline contamination, suggestive of calcium and phosphate compounds, was seen on all screw surfaces. Microbial contamination was more frequently observed in the unsealed group. No differences in bacterial morphotypes were observed between the sealed and unsealed implants. Cocci were the most representative morphotypes, while rods were seldom seen. CONCLUSIONS: In clinical situations, leakage occurs at the implant-abutment interface, although bacterial contamination is limited in patients with high oral hygiene standards. Contamination may be reduced by using a washer device.
Authors: João Paulo da Silva-Neto; Marcel Santana Prudente; Thiago de Almeida Prado Naves Carneiro; Mauro Antônio de Arruda Nóbilo; Mario Paulo Amante Penatti; Flávio Domingues das Neves Journal: J Appl Oral Sci Date: 2012 Sep-Oct Impact factor: 2.698
Authors: Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante Journal: Int J Dent Date: 2011-07-02