Literature DB >> 1180762

[Biomechanical tests on osteosynthesis with small-bone plates (author's transl)].

W Hort, K Diehl.   

Abstract

Plating in handsurgery has become a more frequently used method since the special instruments of the Swiss AO and the self-compression plates of Mittelmeier (made by Osteo AG) have been introduced. The results of biomechanical measurements, comparing the interfragmental compression power and tensile strength of the small-fragment-plates of the AO with the crescent-formed plates of Mittelmeier are reported. The compression power of the first reach their maximum by 8 kp, the latter an average of 20 kp. A gapping of the fracture occures under a deflection-momentum of 4 kp - cm using AO-plates and 10 kp - cm using the crescent-formed plates. The bending stiffness under deflection momentum to the off side of the plate is in the crescent plate 10 times higher. Only an angulating bending in the middle gives in both plates an all over good contact to the fragments. Finger osteosyntheses are very rigid against a deflection momentum in the level of the plate. (Regarding that, we fixe the plate sidewise on the bone.) Our conclusion is, that the better biomechanical stability of the self-compression plates--Mittelmeier-plates--is a result of the higher compression powers.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1180762     DOI: 10.1007/bf00415979

Source DB:  PubMed          Journal:  Arch Orthop Unfallchir        ISSN: 0003-9330


  7 in total

1.  The effect of compression on the rate of fracture healing using a special plate.

Authors:  G W BAGBY; J M JANES
Journal:  Am J Surg       Date:  1958-05       Impact factor: 2.565

2.  An impacting bone plate to attain closed cooptation.

Authors:  C S VENABLE
Journal:  Ann Surg       Date:  1951-06       Impact factor: 12.969

3.  [Compression-osteosynthesis of fresh closed lower-leg schaft fractures using bone screws and bone plates].

Authors:  H Mittelmeier
Journal:  Hefte Unfallheilkd       Date:  1974

4.  [Biomechanical calculations and investigations to the necessity of curved bending at the osteosynthesis with plates (author's transl)].

Authors:  K Diehl
Journal:  Arch Orthop Unfallchir       Date:  1974

5.  [Calculations of strength of pressure-plate-osteosynthesis at location of shaft on long human tubular bones (author's transl)].

Authors:  K Diehl
Journal:  Arch Orthop Unfallchir       Date:  1974

6.  [Biomechanical investigations of "curved bending" of osteosynthesis plates (with special reference to self-compressing pressure-plates) (author's transl)].

Authors:  K Diehl; H Mittelmeier
Journal:  Z Orthop Ihre Grenzgeb       Date:  1974-04

7.  Clinical experience with a new compression plate "DCP".

Authors:  M Allgöwer; R Ehrsam; R Ganz; P Matter; S M Perren
Journal:  Acta Orthop Scand Suppl       Date:  1969
  7 in total