Literature DB >> 11805870

[Comparison of local differential luminance sensitivity (dls) between Oculus Twinfield Perimeter and Humphrey Field Analyzer 630 (HFA I) in normal volunteers of varying ages].

L Lorch1, T J Dietrich, R Schwabe, U Schiefer.   

Abstract

PURPOSE: Purpose of this study was to compare age-corrected normal values of differential luminance sensitivity (dls) of the Oculus Twinfield Perimeter with those of the Humphrey Field Analyzer 630 (HFA I). Furthermore, naso-temporal and superior-inferior asymmetries in the central visual field were analyzed.
METHODS: 72 ophthalmologically normal volunteers, 12 per decade, were examined with both perimeters using a 4-2 dB bracketing strategy with two reversals for threshold estimation. A biometric model, which fits a hill of vision to the data, was developed. The age-related hills, created by the model, were compared between the instruments and analyzed for asymmetries.
RESULTS: The normal dls values for the Twinfield perimeter were about 1.5 dB above those of the HFA I. The shape of the hill in regard to slope in corresponding locations did not differ substantially. The decline of local differential luminance sensitivity showed a nonlinear correlation to age: it remained almost constant up to the 4th decade, with a steeper decline beyond that age. A naso-temporal as well as a superior-inferior asymmetry was found. Along the vertical meridian, the slope of the hill was steeper in the superior part than in the inferior. At an excentricity of 20 degrees we found a superior-inferior difference of 2.1 dB for the HFA and of 1.8 dB for the Twinfield perimeter benefitting the inferior meridian. Along the horizontal meridian there was a distinct difference in regard to the shape of the hill. The sensitivity was greater in the temporal half of the visual field than in the nasal. At an excentricity of 30 degrees, the difference was about 2.75 dB for the HFA and 2.5 dB for the Twinfield perimeter. These asymmetries seem to appear in all age groups. Unfortunately, the exact influence of age on the appearing asymmetries cannot be quantified by the used model.
CONCLUSION: The normal dls values benefit the Twinfield for about 1.5 dB compared to the HFA. There seems to be a critical age of about 40 - 50 years, beyond which a decline of dls becomes manifest.

Entities:  

Mesh:

Year:  2001        PMID: 11805870     DOI: 10.1055/s-2001-19689

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  5 in total

1.  [Static fundus perimetry in normals. Microperimeter 1 versus SLO].

Authors:  C Springer; H E Völcker; K Rohrschneider
Journal:  Ophthalmologe       Date:  2006-03       Impact factor: 1.059

2.  Pattern reversal ERG with LED-stimulation using cyclic summation technique.

Authors:  Barbara Link; Anselm Jünemann; Folkert K Horn
Journal:  Doc Ophthalmol       Date:  2006-01       Impact factor: 2.379

3.  Volume of visual field assessed with kinetic perimetry and its application to static perimetry.

Authors:  John B Christoforidis
Journal:  Clin Ophthalmol       Date:  2011-04-26

4.  Regional Variations and Intra-/Intersession Repeatability for Scotopic Sensitivity in Normal Controls and Patients With Inherited Retinal Degenerations.

Authors:  Lea D Bennett; Georgiana Metz; Martin Klein; Kirsten G Locke; Areeba Khwaja; David G Birch
Journal:  Invest Ophthalmol Vis Sci       Date:  2019-03-01       Impact factor: 4.799

5.  Comparative quantification of focal and diffuse visual field loss by the SPARK Precision threshold algorithm and SITA.

Authors:  S K Foo; R P Cubbidge; R Heitmar
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-12-28       Impact factor: 3.535

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.