Literature DB >> 11804457

Evaluation of the efficacy of lambda-cyhalothrin applied as ultra-low volume and thermal fog for emergency control of Aedes aegypti in Honduras.

M J Perich1, C Sherman, R Burge, E Gill, M Quintana, R A Wirtz.   

Abstract

An extended-duration formulation of lambda-cyhalothrin (Demand CS) applied as either an ultra-low volume (ULV) or thermal fog spray from a new handheld sprayer (Terrier) against Aedes aegypti was evaluated in Honduras. Spray applications were made at the front door for 1 min or to each room for 15 sec, both for the ULV and thermal fog applications to houses in separate blocks for each treatment. The efficacy and duration of effectiveness of the spray was determined from sentinel caged mosquito mortality and collection of mosquitoes within houses with a backpack power aspirator. Sentinel caged mosquito mortality in both open and sequestered locations was 97-100% for all spray treatments, with control mortality less than 2%. Both ULV applications (front door and each room) provided 4 wk of significant control (P < 0.01) based on adult Ae. aegypti house collections.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11804457

Source DB:  PubMed          Journal:  J Am Mosq Control Assoc        ISSN: 8756-971X            Impact factor:   0.917


  8 in total

1.  The efficacy of a combined larvicide-adulticide in ultralow volume and fumigant canister formulations in controlling the dengue vector Aedes aegypti (Diptera: Culicidae) in Northwest of Argentina.

Authors:  Maria J Dantur Juri; Mario Zaidenberg; Mirta Santana
Journal:  Parasitol Res       Date:  2013-01-16       Impact factor: 2.289

2.  Evaluation of Cold and Thermal Fogging Spraying Methods for Mosquito Control.

Authors:  A S Al-Sarar; D Al-Shahrani; H I Hussein; A E Bayoumi; Y Abobakr
Journal:  Neotrop Entomol       Date:  2013-12-12       Impact factor: 1.434

3.  Pyrethroid resistance reduces the efficacy of space sprays for dengue control on the island of Martinique (Caribbean).

Authors:  Sébastien Marcombe; Frédéric Darriet; Michel Tolosa; Philip Agnew; Stéphane Duchon; Manuel Etienne; Marie Michèle Yp Tcha; Fabrice Chandre; Vincent Corbel; André Yébakima
Journal:  PLoS Negl Trop Dis       Date:  2011-06-21

4.  Efficacy of Aedes aegypti control by indoor Ultra Low Volume (ULV) insecticide spraying in Iquitos, Peru.

Authors:  Christian E Gunning; Kenichi W Okamoto; Helvio Astete; Gissella M Vasquez; Erik Erhardt; Clara Del Aguila; Raul Pinedo; Roldan Cardenas; Carlos Pacheco; Enrique Chalco; Hugo Rodriguez-Ferruci; Thomas W Scott; Alun L Lloyd; Fred Gould; Amy C Morrison
Journal:  PLoS Negl Trop Dis       Date:  2018-04-06

5.  Optimizing the deployment of ultra-low volume and targeted indoor residual spraying for dengue outbreak response.

Authors:  Sean M Cavany; Guido España; Alun L Lloyd; Lance A Waller; Uriel Kitron; Helvio Astete; William H Elson; Gonzalo M Vazquez-Prokopec; Thomas W Scott; Amy C Morrison; Robert C Reiner; T Alex Perkins
Journal:  PLoS Comput Biol       Date:  2020-04-20       Impact factor: 4.475

Review 6.  Interventions for vector-borne diseases focused on housing and hygiene in urban areas: a scoping review.

Authors:  Stéphanie Degroote; Kate Zinszer; Valéry Ridde
Journal:  Infect Dis Poverty       Date:  2018-09-03       Impact factor: 4.520

7.  Contact irritant responses of Aedes aegypti Using sublethal concentration and focal application of pyrethroid chemicals.

Authors:  Hortance Manda; Pankhil Shah; Suppaluck Polsomboon; Theeraphap Chareonviriyaphap; Fanny Castro-Llanos; Amy Morrison; Roxanne G Burrus; John P Grieco; Nicole L Achee
Journal:  PLoS Negl Trop Dis       Date:  2013-02-28

Review 8.  Community effectiveness of indoor spraying as a dengue vector control method: A systematic review.

Authors:  Moody Samuel; Dorit Maoz; Pablo Manrique; Tara Ward; Silvia Runge-Ranzinger; Joao Toledo; Ross Boyce; Olaf Horstick
Journal:  PLoS Negl Trop Dis       Date:  2017-08-31
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.