Literature DB >> 11803218

First-trimester ductus venosus velocimetry in relation to nuchal translucency thickness and fetal karyotype.

Maria A Zoppi1, Monica Putzolu, Rosa M Ibba, Marcella Floris, Giovanni Monni.   

Abstract

AIM: To evaluate first-trimester ductus venosus flow in relation to nuchal translucency (NT) and fetal karyotype.
METHODS: Ductus venosus flow was measured in fetuses with NT greater than or equal to the 95th centile (group A) and in fetuses with NT less than the 95th centile (group B). The waveforms were classified as normal if the lowest forward velocity during atrial contraction (ACV) was positive and abnormal if it was absent or negative. The results were compared with the fetal karyotype.
RESULTS: Ductus venosus measurement was carried out in 330 fetuses. In group A, there were 156 fetuses: in 4 cases, it was not possible to obtain the measurement, and in the other 152 cases, 93 (61%) had a normal ACV and 59 (39%) an abnormal ACV. NT thickness was significantly greater in fetuses with abnormal ACV. In 34 out of 156 cases (22%), chromosomal abnormalities were found. Twenty-three chromosomopathies out of 33 (70%) had an abnormal ACV, and 10 (30%) had a normal ACV. A significant association between abnormal karyotype and abnormal ACV was found. Ductus venosus measurement was carried out in 174 fetuses of group B. In 1 case, it was not possible to obtain the measurement. One hundred and seventy-one (99%) cases had a normal ACV, and in 2 (1%) cases the ACV was abnormal. No chromosomal abnormalities were found in group B. Considering group A and group B, a significant association between the finding of an enlarged NT and abnormal ACV was detected (p < 0.05).
CONCLUSIONS: An abnormal ACV is more frequent in fetuses presenting enlarged NT than in those having normal NTs and in fetuses having the larger nuchal thickness. The probability of having a chromosomal abnormality in fetuses with enlarged NT is greater when an abnormal ACV is found. Copyright 2002 S. Karger AG, Basel

Entities:  

Mesh:

Year:  2002        PMID: 11803218     DOI: 10.1159/000048007

Source DB:  PubMed          Journal:  Fetal Diagn Ther        ISSN: 1015-3837            Impact factor:   2.587


  2 in total

1.  Human fetal cardiac function during the first trimester of pregnancy.

Authors:  K Mäkikallio; P Jouppila; J Räsänen
Journal:  Heart       Date:  2005-03       Impact factor: 5.994

2.  Employ ductus venous blood flow in the early detection of trisomy 21, trisomy 18, and trisomy 13: A meta-analysis.

Authors:  Yibing Ge; Lili Xia; Yun Wu; Hongbao Cao
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.