An in situ adjustable endovascular graft for the treatment of abdominal aortic aneurysms.

Bruce J Brener1, Peter Faries, Timothy Connelly, Vladmir Sefranek, Steven Hertz, Lee Kirksey, Larry Hollier, Michael L Marin.   

Abstract

Twenty-nine patients underwent placement of the Teramed Ariba Endovascular Graft System (Maple Grove, Minn) as part of a European Feasibility study (14 patients) and a US phase I trial (15 patients). Salient features of this modular endograft system include a crimped seamless polyester bifurcation graft supplied in three diameters and three iliac limb lengths, three types of nitinol stents including a suprarenal stent with aortic barbs, a flexible delivery system capable of controlled incremental sheath retraction, a flexible tapered lead balloon, and a telescoping technique for adjusting the length of graft coverage during surgery over a range of 3 cm. Twenty-eight of the 29 patients met the primary objective of this evaluation, which was to confirm the safety of the system, defined as the absence of major device-related adverse events and type I, III, or IV endoleaks within 1 month of implantation. Three major adverse events occurred within 1 month of discharge: renal failure, which was related to deployment of the device close to the renal arteries; pulmonary edema, which was related to the procedure but not the device; and peripheral ischemia, which was related to the patient's pre-existing condition. Seven patients had type II endoleaks noted by means of computed tomography scanning at 1 month; the endoleaks were identified by means of angiography and classified at the time of surgery. There were no deaths, aneurysm ruptures, stent-graft migrations, stent fractures, graft ruptures, graft thromboses, or surgical conversions at 1 month. This early clinical experience indicates that the Ariba Bifurcated Endovascular System can be safely implanted.

Entities:  

Mesh:

Year:  2002        PMID: 11802141     DOI: 10.1067/mva.2002.119748

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  2 in total

1.  Devices used for endovascular aneurysm repair: past, present, and future.

Authors:  Benjamin M Jackson; Jeffrey P Carpenter
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

2.  Endovascular stent graft repair of abdominal and thoracic aortic aneurysms: a ten-year experience with 817 patients.

Authors:  Michael L Marin; Larry H Hollier; Sharif H Ellozy; David Spielvogel; Harold Mitty; Randall Griepp; Robert A Lookstein; Alfio Carroccio; Nicholas J Morrissey; Victoria J Teodorescu; Tikva S Jacobs; Michael E Minor; Claudie M Sheahan; Kristina Chae; Juliana Oak; Andrew Cha
Journal:  Ann Surg       Date:  2003-10       Impact factor: 12.969

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.