Literature DB >> 11800135

Ultrasonic tissue characterization using a generalized Nakagami model.

P M Shankar.   

Abstract

The statistics of the backscattered ultrasonic echo from tissue have been described using Rayleigh, K, and Nakagami distributions. The Nakagami and K distributions, each with two parameters, can model the envelope reasonably well. However, a three-parameter distribution is likely to match the envelope of the backscattered echo much better than these two-parameter distributions. Starting with the Nakagami distribution and including an additional parameter to account for the tails of the density function, a generalized Nakagami distribution has been derived. Computer simulation of A-scans and analysis of data collected from tissue-mimicking phantoms show that the generalized Nakagami distribution fits the statistics of the echo of the envelope better than the Nakagami distribution. The parameters of the generalized Nakagami distribution appear to be far more sensitive to the scattering conditions than the parameters of the Nakagami distribution.

Entities:  

Mesh:

Year:  2001        PMID: 11800135     DOI: 10.1109/58.971725

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  19 in total

1.  Robust non-homomorphic approach for speckle reduction in medical ultrasound images.

Authors:  S Gupta; R C Chauhan; S C Saxena
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

2.  Analysis of fluctuation for pixel-pair distance in co-occurrence matrix applied to ultrasonic images for diagnosis of liver fibrosis.

Authors:  Hiroshi Isono; Shinnosuke Hirata; Tadashi Yamaguchi; Hiroyuki Hachiya
Journal:  J Med Ultrason (2001)       Date:  2016-10-18       Impact factor: 1.314

3.  Quantitative Ultrasonic Nakagami Imaging of Neck Fibrosis After Head and Neck Radiation Therapy.

Authors:  Xiaofeng Yang; Emi Yoshida; Richard J Cassidy; Jonathan J Beitler; David S Yu; Walter J Curran; Tian Liu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-25       Impact factor: 7.038

4.  Ultrasonic Nakagami-parameter characterization of parotid-gland injury following head-and-neck radiotherapy: a feasibility study of late toxicity.

Authors:  Xiaofeng Yang; Srini Tridandapani; Jonathan J Beitler; David S Yu; Ning Wu; Yuefeng Wang; Deborah W Bruner; Walter J Curran; Tian Liu
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

5.  Proposal of a parametric imaging method for quantitative diagnosis of liver fibrosis.

Authors:  Tadashi Yamaguchi; Hiroyuki Hachiya
Journal:  J Med Ultrason (2001)       Date:  2010-07-13       Impact factor: 1.314

Review 6.  Thermometry and ablation monitoring with ultrasound.

Authors:  Matthew A Lewis; Robert M Staruch; Rajiv Chopra
Journal:  Int J Hyperthermia       Date:  2015-03-10       Impact factor: 3.914

7.  Modeling the envelope statistics of three-dimensional high-frequency ultrasound echo signals from dissected human lymph nodes.

Authors:  Thanh Minh Bui; Alain Coron; Jonathan Mamou; Emi Saegusa-Beecroft; Tadashi Yamaguchi; Eugene Yanagihara; Junji Machi; S Lori Bridal; Ernest J Feleppa
Journal:  Jpn J Appl Phys (2008)       Date:  2014       Impact factor: 1.480

8.  Noninvasive evaluation of vaginal fibrosis following radiotherapy for gynecologic malignancies: a feasibility study with ultrasound B-mode and Nakagami parameter imaging.

Authors:  Xiaofeng Yang; Peter Rossi; Deborah Watkins Bruner; Srini Tridandapani; Joseph Shelton; Tian Liu
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

9.  Monitoring tissue inflammation and responses to drug treatments in early stages of mice bone fracture using 50 MHz ultrasound.

Authors:  Yen-Chu Chen; Yi-Hsun Lin; Shyh-Hau Wang; Shih-Ping Lin; K Kirk Shung; Chia-Ching Wu
Journal:  Ultrasonics       Date:  2013-07-11       Impact factor: 2.890

10.  Burr, Lomax, Pareto, and Logistic Distributions from Ultrasound Speckle.

Authors:  Kevin J Parker; Sedigheh S Poul
Journal:  Ultrason Imaging       Date:  2020-06-02       Impact factor: 1.578

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.