Percutaneous closure of ductus arteriosus with the amplatzer prosthesis. The Brazilian experience.

L C Simões, C A Pedra, C A Esteves, R Camargo, S L Braga, P Loureiro, M A Santos, V F Fontes.   

Abstract

OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0+/-1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4+/-3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.

Entities:  

Mesh:

Year:  2001        PMID: 11799427     DOI: 10.1590/s0066-782x2001001200003

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


  4 in total

1.  Update on the Amplatzer duct occluder: a 10-year experience in Asia.

Authors:  Charles C Cuaso; Reina Bianca M Tan; Jonas D Del Rosario; Dexter D Cheng; Karl G Reyes
Journal:  Pediatr Cardiol       Date:  2011-11-22       Impact factor: 1.655

Review 2.  An Up-to-Date Narrative Review on Congenital Heart Disease Percutaneous Treatment in Children Using Contemporary Devices.

Authors:  Stefana Maria Moisa; Alexandru Burlacu; Crischentian Brinza; Elena Țarcă; Lăcrămioara Ionela Butnariu; Laura Mihaela Trandafir
Journal:  Diagnostics (Basel)       Date:  2022-05-10

3.  The Amplatzer duct occluder for PDA closure: indications, technique of implantation and clinical outcome.

Authors:  W Boehm; M Emmel; N Sreeram
Journal:  Images Paediatr Cardiol       Date:  2007-04

4.  Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results.

Authors:  Santosh Kumar Sinha; Mahmadula Razi; Rama Niwas Pandey; Prakash Kumar; Vinay Krishna; Mukesh Jitendra Jha; Vikas Mishra; Mohammad Asif; Nasar Abdali; Pradyot Tewari; Ramesh Thakur; Umeshwar Pandey; Chandra Mohan Varma
Journal:  Anatol J Cardiol       Date:  2017-11       Impact factor: 1.596