The magnitude of signal errors introduced by ISIS in quantitative 31P MRS.

Maria Ljungberg1, Göran Starck, Barbro Vikhoff-Baaz, Magne Alpsten, Sven Ekholm, Eva Forssell-Aronsson.   

Abstract

It is well known that the quality of a quantitative 31P MRS measurement relies largely on the performance of the volume selection method, and that image selected in vivo spectroscopy (ISIS) suffers from contaminating signal caused mostly by T1 smearing. However, these signal errors and their magnitude are seldom addressed in clinical studies. The aim of this study was therefore to investigate the magnitude of signal errors in 31P MRS when using ISIS. The results from the measurements with a homogeneous head phantom are as follows: at low TR/T1 ratios the contamination increases rapidly, especially for small (<27 cm3) VOI sizes; at TR/T1=1, the signal from a 27 cm3 VOI was 20% too high, and from an 8 cm3 VOI 150% too high. The signal obtained from different VOI positions varied between 80 and 127%. The signal varied linearly with the 31P concentration in the object. However, a too high signal was obtained when the concentration was lower in the region of interest (inner container) than in the rest of the phantom. The agreement between the simulations and measurements shows that the results of this study are generally applicable to the measurement geometry and the ISIS experiment order rather than being specific for the MR system studied. The errors obtained both experimentally and in computer simulations are too large to be ignored in clinical studies using the ISIS pulse sequence.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11796250     DOI: 10.1007/BF02668184

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.533


  12 in total

1.  Extended ISIS sequences insensitive to T(1) smearing.

Authors:  M Ljungberg; G Starck; B Vikhoff-Baaz; M Alpsten; S Ekholm; E Forssell-Aronsson
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  The impact of the ISIS experiment order on spatial contamination.

Authors:  C Burger; R Buchli; G McKinnon; D Meier; P Boesiger
Journal:  Magn Reson Med       Date:  1992-08       Impact factor: 4.668

3.  Signal profile measurements of single- and double-volume acquisitions with image-selected in vivo spectroscopy for 31P magnetic resonance spectroscopy.

Authors:  M Ljungberg; G Starck; B Vikhoff-Baaz; E Forssell-Aronsson; M Alpsten; S Ekholm
Journal:  Magn Reson Imaging       Date:  1998-09       Impact factor: 2.546

4.  Computer simulation of MRS localization techniques: an analysis of ISIS.

Authors:  T J Lawry; G S Karczmar; M W Weiner; G B Matson
Journal:  Magn Reson Med       Date:  1989-03       Impact factor: 4.668

Review 5.  A critical assessment of methods of measuring metabolite concentrations by NMR spectroscopy.

Authors:  P S Tofts; S Wray
Journal:  NMR Biomed       Date:  1988-02       Impact factor: 4.044

6.  Alzheimer dementia: quantification of energy metabolism and mobile phosphoesters with P-31 NMR spectroscopy.

Authors:  P A Bottomley; J P Cousins; D L Pendrey; W A Wagle; C J Hardy; F A Eames; R J McCaffrey; D A Thompson
Journal:  Radiology       Date:  1992-06       Impact factor: 11.105

7.  Evaluation of volume selection methods in in vivo MRS. Design of a new test phantom.

Authors:  G Starck; R Lundin; E Forssell-Aronsson; M Arvidsson; M Alpsten; S Ekholm
Journal:  Acta Radiol       Date:  1995-05       Impact factor: 1.990

8.  Quality assessment in in vivo NMR spectroscopy: III. Clinical test objects: design, construction, and solutions.

Authors:  M O Leach; D J Collins; S Keevil; I Rowland; M A Smith; O Henriksen; W M Bovée; F Podo
Journal:  Magn Reson Imaging       Date:  1995       Impact factor: 2.546

9.  Selective population inversion in NMR.

Authors:  M S Silver; R I Joseph; C N Chen; V J Sank; D I Hoult
Journal:  Nature       Date:  1984 Aug 23-29       Impact factor: 49.962

10.  Experimental approaches to image localized human 31P NMR spectroscopy.

Authors:  P R Luyten; J P Groen; J W Vermeulen; J A den Hollander
Journal:  Magn Reson Med       Date:  1989-07       Impact factor: 4.668

View more
  1 in total

1.  Absolute quantification of human liver metabolite concentrations by localized in vivo 31P NMR spectroscopy in diffuse liver disease.

Authors:  Bengt Norén; Peter Lundberg; Marcus Ressner; Staffan Wirell; Sven Almer; Orjan Smedby
Journal:  Eur Radiol       Date:  2004-09-03       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.